ENGINE - DIESEL FUEL<4N1> - SUPPLY PUMP
SUPPLY PUMP REMOVAL AND INSTALLATION
N502550430000B00ENG
CAUTION:
  • When the supply pump assembly is replaced, perform the followings (Refer to WHAT THE COMMON RAIL ENGINE LEARNS).
    • Supply pump learning value initialisation
    • Supply pump correction learning
  • During removal and installation of the supply pump assembly and tappet, be aware of the followings.
    • Be careful not to damage the inside diameter of the pump engagement hole on the cylinder block.
    • Be careful not to adhere or lodge the foreign matter into the supply pump assembly or tappet.
    • Do not use the supply pump assembly or tappet that has been dropped or being damaged.
    • Do not hold the electrical connector, fuel inlet/outlet, insertion part or pulsation damper.
  • During removal of the supply pump assembly, be aware of the following.
    • The supply pump is fastened by compressing the spring, so if you try to remove the pump after removing the mounting bolt, the spring reaction force may cause the pump to pop out. For safety, repeat the process of "loosen the two mounting bolts to the same height" ↔ "release the compression of the spring".
Pre-removal Operation
Post-installation Operation
Removal steps
•
Alternator connector connection (Refer to Engine – Engine Electrical – Charging System – ALTERNATOR ASSEMBLY REMOVAL AND INSTALLATION)
•
Alternator terminal B connection (Refer to Engine – Engine Electrical – Charging System – ALTERNATOR ASSEMBLY REMOVAL AND INSTALLATION)
•
EGR gas temperature sensor (Refer to Engine – Intake and Exhaust – INLET MANIFOLD REMOVAL AND INSTALLATION)
1.
Supply pump connector connection
•
Manifold absolute pressure sensor connector connection (Refer to Engine – Engine Overhaul – SOLENOID VALVE AND VACUUM HOSE REMOVAL AND INSTALLATION)
2.
Fuel tube assembly
3.
Fuel return pipe C
•
Manifold absolute pressure sensor (Refer to Engine – Engine Overhaul – SOLENOID VALVE AND VACUUM HOSE REMOVAL AND INSTALLATION)
•
Vacuum hose B (Manifold absolute pressure sensor side) connection (Refer to Engine – Engine Overhaul – SOLENOID VALVE AND VACUUM HOSE REMOVAL AND INSTALLATION)
4.
Fuel feed pipe
5.
Fuel return hose connection
6.
Fuel return hose F
7.
Fuel return pipe A
8.
Gasket
9.
Supply pump assembly
10.
O-ring seal
11.
Tappet
INSTALLATION SERVICE POINTS
>>A<< TAPPET/SUPPLY PUMP ASSEMBLY INSTALLATION
To rotate the supply pump camshaft from the top dead centre position to the bottom dead centre position, rotate the crankshaft 90° clockwise from the top dead centre position.
Remove all the residual sealant from the threaded holes in the supply pump housing.
CAUTION:
  • When inserting the tappet into the supply pump housing, be careful to fit the dowel pin end of the supply pump housing into the groove on the side of the tappet.
  • Be careful not to vigorously drop the tappet on the cam and damage the cam or the tappet.
Apply the engine oil to the roller surface and the side surface of the tappet, then insert the tappet into the supply pump housing.
CAUTION:
  • When pushing do not touch the electrical connector and be careful not to pinch the o-ring seal of the supply pump assembly in the seating surface of the supply pump housing.
  • Be careful not to apply abnormal external force to the lower seat.
Apply engine oil to the contact surface between the supply pump assembly and the tappet, and insertion surface between the supply pump assembly and the supply pump housing.
CAUTION:
  • In order to confirm that the tappet is inserted in the correct position (the dowel pin end of the supply pump housing is fit into the groove on the side of the tappet), manually insert the supply pump assembly into the supply pump housing, and make sure that the gap between the seating surfaces is approximately 10 mm or less.
  • If the amount of the gap between the seating surfaces is not within the specified range shown in the illustration, check the tappet installation direction.
  • If the seating surfaces are matching face-to-face as shown in the illustration, the tappet may not be inserted into the supply pump housing.
Insert the supply pump.
CAUTION:
When temporarily tightening the supply pump assembly mounting bolts, be aware of the followings.
  • Temporarily tighten the bolts by manually rotating them by hand.
  • Be careful not to lean the supply pump assembly and keep it horizontal against the seating surface of the supply pump housing, so that the spring is compressed straight against the supply pump housing.
Temporarily tighten two supply pump assembly mounting bolts alternately by 45° or less until the seating surface of the supply pump assembly and the supply pump housing are in close contact.
Tighten the supply pump mounting bolts to the specified torque.
Tightening torque: 29 ± 3 N·m