ENGINE - DIESEL FUEL<4N1> - TROUBLESHOOTING - DIAGNOSIS CODE PROCEDURES - P0642-00 Sensor reference voltage A
DTC Description: P0642-00
N502553670000C00ENG
DIAGNOSIS CODE DETECTION LOGIC
Diagnosis Code No.
M.U.T.-III SE Screen Items
[Diagnosis item]
Diagnosis Code Detection Condition
P0642-00
Sensor reference voltage A
[Sensor power supply circuit low1 ]
Diagnosis condition
  • Battery positive voltage is 8 to 16 V.
  • 2 seconds have passed after the ignition switch is turned to "ON" position or the engine is started.
Signal (terminal)
–
Threshold
The detected voltage of analog sensor reference voltage No. 1 is 4.86 V or less. [Power supply for accelerator pedal position sensor (main)]
Diagnosis delay time
–
POSSIBLE CAUSE
Failed engine-ECU
FAIL-SAFE AND BACKUP FUNCTION
  • The accelerator pedal opening is controlled to be 0%.
  • The idle speed is 1,300 r/min.
  • The DPF regeneration is prohibited. <Euro 5b, Euro 6b or Euro 6c>
  • The throttle valve is closed (Fixed opening degree).
  • The turbocharger control is prohibited.
  • The small injection quantity learning is prohibited.
  • The turbo bypass valve control is prohibited. <SHP engine>
  • The V.V.T. system control is prohibited. <SHP engine>
  • The cruise control is prohibit. <Vehicles with cruise control system>
  • The speed limiter control is prohibited. <Vehicles with speed limiter function>
DIAGNOSIS CODE CONFIRMATION PROCEDURE
1.Preconditioning
If "Diagnosis Code Confirmation Procedure" has been previously conducted, always turn the ignition switch to the "LOCK" (OFF) position and wait at least 65 seconds before conducting the next test.
2.Diagnosis code confirmation procedure
CAUTION:
To prevent damage to the M.U.T.-III SE, always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting the M.U.T.-III SE.
With M.U.T.-III SE
  1. Turn the ignition switch to the "ON" position and wait for 10 seconds or more.
  2. Perform "Self-diagnosis" of engine-ECU using M.U.T.-III SE.
Is diagnosis code No. P0642-00 set?
YES
NO-1
To check malfunction symptom before repair: Check intermittent incident (Refer to General Information – General – Basic Inspection – Service Information for Electrical Incident – INTERMITTENT INCIDENT).
NO-2
Confirmation after repair: Inspection end
BookmarkedToo many bookmarks.