ENGINE - DIESEL FUEL<4N1> - TROUBLESHOOTING - DIAGNOSIS CODE PROCEDURES - P1299-00 Turbocharger/Supercharger A<SHP engine>
DTC Description: P1299-00
N502553790000800ENG
DIAGNOSIS CODE DETECTION LOGIC
Diagnosis Code No.
M.U.T.-III SE Screen Items
[Diagnosis item]
Diagnosis Code Detection Condition
P1299-00
Turbocharger/Supercharger A
[Variable geometry turbocharger control system malfunction (low pressure)]
Diagnosis condition
  • Battery positive voltage is 8 to 16 V.
  • 2 seconds have passed after the ignition switch is turned to "ON" position.
  • Engine is running
Signal (terminal)
–
Threshold
Actual boost pressure is lower than target boost pressure by less than specified.
Diagnosis delay time
8 seconds
POSSIBLE CAUSE
  • Failed intake system (air leak/air suction) [Air filter (air flow sensor part) to inlet manifold (cylinder head joint part)].
  • Failed manifold absolute pressure sensor hose (air leak/air suction).
  • Failed turbocharger (VG actuator, turbine bypass valve actuator, waste gate valve actuator, compressor bypass valve actuator).
  • Failed waste gate valve control solenoid valve.
  • Failed compressor bypass valve control solenoid valve.
  • Failed intercooler (clogged).
  • Failed EGR cooler (clogged).
  • Failed EGR pipe (clogged).
  • Failed engine-ECU.
FAIL-SAFE AND BACKUP FUNCTION
  • The EGR system control is prohibited (fully closed).
  • The fuel injection amount is restricted (Output restriction).
  • The small injection quantity learning is prohibited.
  • The speed limiter control is prohibited. <Vehicles with speed limiter function>
  • The cruise control is prohibit. <Vehicles with cruise control system>
DIAGNOSIS CODE CONFIRMATION PROCEDURE
1.Preconditioning
If "Diagnosis Code Confirmation Procedure" has been previously conducted, always turn the ignition switch to the "LOCK" (OFF) position and wait at least 65 seconds before conducting the next test.
2.Diagnosis code confirmation procedure
CAUTION:
To prevent damage to the M.U.T.-III SE, always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting the M.U.T.-III SE.
With M.U.T.-III SE
  1. Turn the ignition switch to the "LOCK" (OFF) position and wait for 1 minute or more.
  2. Start the engine.
  3. Wait for 20 seconds or more in idling condition.
  4. Perform "Self-diagnosis" of engine-ECU using M.U.T.-III SE.
Is diagnosis code No. P1299-00 set?
YES
NO-1
To check malfunction symptom before repair: Check intermittent incident (Refer to General Information – General – Basic Inspection – Service Information for Electrical Incident – INTERMITTENT INCIDENT).
NO-2
Confirmation after repair: Inspection end.
BookmarkedToo many bookmarks.
Please delete and bookmark again.