The operating time of the urea injector cooling system is calculated from the values of exhaust temperature sensor No. 2 and A/C condenser temperature sensor (ambient temperature sensor). If the exhaust temperature sensor No. 2 fails, the operating time of the urea injector cooling system cannot be calculated correctly and the urea injector assembly may also be faulty. After repairing exhaust temperature sensor No. 2, check that there is no malfunction in the urea injector assembly.