ENGINE - INTAKE AND EXHAUST - SPECIFICATIONS
SERVICE SPECIFICATIONS
N502580030000600ENG
Item
Standard value
Limit
Turbocharger supercharging pressure kPa
4N1 Low-power engine
201 to 267
-
4N1 Normal-power engine
231 to 322
-
4N1 High-power engine
248 to 355
-
4N1 Super high-power engine
276 to 330
-
Variable geometry actuator resistance (at 25 °C) Ω
4N1 Except Super high-power engine
Maximum 1.9
-
Variable geometry actuator resistance (at 25 °C) Ω
4N1 Super high-power engine
Maximum 2.875
-
Turbine bypass valve actuator resistance (at 25 °C) Ω
4N1 Super high-power engine
Maximum 2.59
-
Turbocharger waste gate valve control solenoid valve coil resistance (at 20 °C) Ω
4N1 Super high-power engine
14.8 to 16.2
-
Turbocharger compressor bypass valve control solenoid valve coil resistance (at 20 °C) Ω
4N1 Super high-power engine
29 to 35
-
Inlet manifold distortion of the installation surface mm
4G6
0.15 or less
0.20
Exhaust manifold distortion of the installation surface mm
4G6
0.5 or less
0.7
4N1 (Cylinder head side)
0.15
0.7
4N1 (Turbocharger side)
0.1
0.5
BookmarkedToo many bookmarks.