ENGINE - INTAKE AND EXHAUST - ON-VEHICLE SERVICE
TURBINE BYPASS VALVE ACTUATOR CHECK <4N1 SUPER HIGH-POWER ENGINE>
N502580420000H01ENG
RESISTANCE BETWEEN TERMINALS CHECK
Disconnect the turbine bypass valve actuator connector.
Measure the resistance between terminal No. 1 and No. 5.
Standard value: Maximum 2.59 Ω (at 25°C)
If the resistance deviates from outside the standard value, replace the turbocharger assembly.
Check the electrical continuity of the points shown in the table below. Confirm that there is not electrical continuity. If there is, replace the turbocharger assembly.
Measured terminal No.
Electrical continuity
5-2
Absence of electrical continuity
5-3
5-4
OPERATION CHECK
At the ignition switch is the "ON" position, perform the following engine-ECU actuator test item and confirm that the turbine bypass valve moves. If the turbine bypass valve is not moving, replace the turbocharger assembly (Refer to TURBOCHARGER ASSEMBLY REMOVAL AND INSTALLATION)
Item No.
M.U.T.-III SE display
Drive contents
Inspection conditions
Normal condition
16
Turbine bypass valve
Open the turbine bypass valve into 0 to 100%
  • Ignition switch: "ON" position
  • Vehicle stopped
  • Turbine bypass valve drives.
  • The value is reflected to the turbine bypass valve target opening degree.
NOTE:
Make sure that the harness is not loosen and connector is not disconnected before the operation check.