ENGINE - ENGINE AND EMISSION CONTROL - EMISSION CONTROL<4N1> - UREA SCR SYSTEM<EURO 6B OR EURO 6C> - ON-VEHICLE SERVICE
AdBlue® REFILL
N502630570000F00ENG
CAUTION:
  • Do not refill the urea tank with diesel exhaust fluid other than AdBlue®.
  • If any AdBlue® gets on painted surfaces, wash it off immediately with clean water.
  • If the AdBlue® is adhered to the vehicle, wipe the area with a wet cloth.
<When replenishing by confirming the maximum refill quantity by the M.U.T.-III SE>
CAUTION:
To prevent damage to the M.U.T.-III SE, always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting the M.U.T.-III SE.
Connect the M.U.T.-III SE to the diagnosis connector.
Turn the ignition switch to "ON" position (But do not start the engine).
Check "Item No. 44: Urea tank remaining volume(L)" from the M.U.T.-III SE data list.
Confirm the maximum refill quantity in the table below according to the value read out in Step 3.
Item No. 43: Urea tank remaining volume (%)*1
Item No. 44: Urea tank remaining volume (L)
Item No. 45: Urea tank remaining volume (g)*2
Item No. 46: Urea tank level sensor (filtered value) (mm)
Item No. 79: Remaining mile urea refill warning (km)*3
Maximum refill quantity (L)*4
[0]
1.47
[1602.3]
47.4
0
17
[2.745]
1.753
[1910.77]
50
308.47
16.717
[9.412]
3.205
[3493.45]
60
1891.15
15.265
[23.922]
4.741
[5167.69]
70
3565.39
13.729
[30.98]
6.325
[6894.25]
80
5291.95
12.145
[38.824]
7.94
[8654.6]
90
7052.3
10.53
[54.118]
9.577
[10438.93]
100
8836.63
8.893
[61.569]
11.227
[12237.43]
110
10635.13
7.243
[69.412]
12.883
[14042.47]
120
12440.17
5.587
[84.706]
14.531
[15838.79]
130
14236.49
3.939
[100]
17
[18530]
145.25
16927.7
1.47
NOTE:
  • [ ]: Reference value.
    • Since the urea tank remaining volume in litres (L) can be directly read out, the remaining amount in percent (%) and grams (g) is described as reference only.
  • *1: If more AdBlue than the nominal capacity is replenished, the urea tank remaining volume (%) displayed may be more than 100%.
  • *2: The urea tank remaining volume (g) is a value calculated by multiplying the remaining amount in litres by the AdBlue concentration. The above value is based on the assumption that the concentration at room temperature is 1090 (g/L). Therefore, the values ​​in the table may deviate depending on the AdBlue temperature.
  • *3: This is only for reference because the urea consumption amount varies depending on the driving conditions.
  • *4: It is no problem if the refill quantity is less than this value because this is the maximum refill quantity.
After turning the ignition switch to the "LOCK" (OFF) position, remove the M.U.T.-III SE.
Replenish AdBlue™ via the AdBlue™ refill port by considering the maximum refill quantity which you confirmed in Step 4.
NOTE:
  • Only when the AdBlue® remaining amount warning is displayed on the combination meter, proceed to Step 7.
  • When rechecking the maximum refill quantity after replenishing AdBlue®, be sure to perform Step 7 through Step 12 before the recheck.
Connect the M.U.T.-III SE to the diagnosis connector.
Turn the ignition switch to "ON" position (But do not start the engine).
Select "UDCU" from System Select Screen of the M.U.T.-III SE.
From UDCU Screen, select "Special Function".
From Special Function Screen, select "Initialization".
Carry out "Item No. 11: Urea tank level update" from Initialization Screen of the M.U.T.-III SE.
Check that the AdBlue™ remaining amount warning has disappeared from the combination meter.
NOTE:
If the refill quantity at one time is 4 litres or more, the AdBlue® remaining amount warning can be turned off without performing the urea tank level reset. The warning can be turned off by performing the following procedure. Stop the vehicle on a level surface, and turn the ignition switch from "LOCK" (OFF) to "ON" (do not start the engine). Then, leave the vehicle for approximately 5 minutes or more.
After turning the ignition switch to the "LOCK" (OFF) position, remove the M.U.T.-III SE.
<When the AdBlue® remaining amount warning is displayed on the combination meter>
Confirm the travelable distance of the AdBlue® remaining amount warning displayed on the combination meter.
By referring to the table below, confirm the maximum refill quantity according to the travelable distance.
<k/m>
Travelable distance display
Maximum refill quantity (L)*
Travelable distance display
Maximum refill quantity (L)*
2,400 km
[14.798]
400 km
[16.633]
2,100 km
[15.073]
200 km
[16.817]
1,800 km
[15.349]
100 km
[16.908]
1,500 km
[15.624]
60 km
[16.945]
1,200 km
[15.899]
40 km
[16.963]
900 km
[16.174]
20 km
[16.982]
600 km
[16.450]
10 km
[16.991]
<mile>
Travelable distance display
Maximum refill quantity (L)*
Travelable distance display
Maximum refill quantity (L)*
1,500 mile
[14.798]
300 mile
[16.560]
1,300 mile
[15.092]
200 mile
[16.706]
1,100 mile
[15.385]
100 mile
[16.853]
900 mile
[15.679]
60 mile
[16.912]
700 mile
[15.972]
40 mile
[16.941]
500 mile
[16.266]
20 mile
[16.971]
400 mile
[16.413]
10 mile
[16.985]
NOTE:
  • [ ]: Reference value.
    • Since the urea tank remaining volume in litres (L) can be directly read out, the maximum refill quantity (L) information is described as reference only.
  • *: It is no problem if the refill quantity is less than this value because this is the maximum refill quantity. However, the refill quantity at one time should be more than 4 litres because the travelable distance will not be updated if the refill quantity is 4 litres or less.
Replenish AdBlue® via the AdBlue® refill port by considering the maximum refill quantity which you confirmed in Step 2.
Turn the ignition switch to the "ON" position, and leave the vehicle for approximately 5 minutes.
Check that the AdBlue® remaining amount warning has disappeared from the combination meter.
If the AdBlue® remaining amount warning does not go out, turn off the AdBlue® remaining amount warning by the following procedures.
CAUTION:
To prevent damage to the M.U.T.-III SE, always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting the M.U.T.-III SE.
Connect the M.U.T.-III SE to the diagnosis connector.
Turn the ignition switch to "ON" position (But do not start the engine).
Select "UDCU" from System Select Screen of the M.U.T.-III SE.
From DCU Screen, select "Special Function".
From Special Function Screen, select "Initialization".
Carry out "Item No. 11: Urea tank level update" from Initialization Screen of the M.U.T.-III SE.
Check that the AdBlue® remaining amount warning has disappeared from the combination meter.
NOTE:
If the refill quantity at one time is 4 litres or more, the AdBlue® remaining amount warning can be turned off without performing the urea tank level reset. The warning can be turned off by performing the following procedure. Stop the vehicle on a level surface, and turn the ignition switch from "LOCK" (OFF) to "ON" (do not start the engine). Then, leave the vehicle for approximately 5 minutes or more.
After turning the ignition switch to the "LOCK" (OFF) position, remove the M.U.T.-III SE.
BookmarkedToo many bookmarks.