ENGINE - ENGINE AND EMISSION CONTROL - EMISSION CONTROL<4N1> - UREA SCR SYSTEM<EURO 6B OR EURO 6C> - UREA TANK
UREA TANK DISASSEMBLY AND REASSEMBLY
N502630750000A00ENG
CAUTION:
The removed urea pump can be reassembled up to 3 times. To count the number of urea pump reassembly, record it by adding the reassembly number of this time (once usually) to the previous number of reassembly written on the maintenance handbook. When the number of the previous reassembly reaches 3 or when the urea pump is replaced, always use a new urea pump. At that time, write "New (0 times)" in the maintenance handbook.
Urea pump disassembly steps
1.
Urea tank protector (front side)
2.
Urea tank protector (under)
3.
Urea line tube C connection
4.
Urea tank harness connector connection
5.
Urea tank assembly
6.
Urea pump assembly
7.
Urea pump
8.
Seal
9.
Sleeve
10.
Damper
REMOVAL SERVICE POINT
<<A>> UREA PUMP/SEAL/SLEEVE/DAMPER REMOVAL
CAUTION:
When removing the urea pump, do not touch or contaminate the DAE membrane indicated by the arrow in the illustration.
Remove urea pump mouting bolts.
Insert a slotted head screw driver between the urea tank assembly and the urea pump assemly (see the slope besides the marking "A" in the illustration) and with the help of a slotted head screw driver, lever out the urea pump assembly with less force.
Remove seals, sleeves and dampers from the urea pump assembly.
INSTALLATION SERVICE POINTS
>>A<< DAMPER/SLEEVE/SEAL/UREA PUMP INSTALLATION
CAUTION:
When installing the urea pump, do not touch or contaminate the DAE membrane indicated by the arrow in the illustration.
CAUTION:
The seals and the internal hydraulic interfaces of the urea pump assembly have to be moistened with assembly lubricant before installation in the urea pump as shown in the illustration.
Install the urea pump with new seals, sleeves and dampers using the mounting bolts.
Tighten the urea pump mounting bolts to the specified torque in the order of number shown in the illustration.
Tightening torque: 5.75 ± 0.4 N·m
By considering the tightening characteristics, all screws must be re-tightened after 120 seconds or more. Re-tightening should be carried out according to the order and the specified torque shown above.
>>B<< UREA TANK ASSEMBLY/UREA TANK PROTECTOR (UNDER) INSTALLATION
Before installing, follow the steps below to put the urea tank protector (under) and the urea tank assembly in a sub-assembly.
NOTE:
The urea tank protector (under) and the urea tank assembly need to be sub-assembled because they are co-tightening to the vehicle body.
CAUTION:
Make sure that the fastening surfaces of the urea tank protector (under) and the urea tank assembly are seated when urea tank protector (under) is set on top of the urea tank assembly.
As shown in the illustration, place the urea tank assembly on the flat surface, then set the urea tank protector (under) on top of the urea tank assembly.
Tighten the mounting bolts of the urea tank protector (under) to the specified torque.
Tightening torque: 12 ± 1 N·m