ENGINE - ENGINE AND EMISSION CONTROL - EMISSION CONTROL<4N1> - UREA SCR SYSTEM<EURO 6B OR EURO 6C> - UREA SCR TROUBLESHOOTING - DIAGNOSIS CODE PROCEDURES - P202A-92 Urea Tank Heater Control Circuit Performance
DTC Description: P202A-92
N502631200000100ENG
DIAGNOSIS CODE DETECTION LOGIC
Diagnosis Code No.
M.U.T.-III SE Screen Item
[Diagnosis item]
Diagnosis Code Detection Condition
P202A-92
Urea Tank Heater Control Circuit Performance
[Urea tank heater control circuit rerformance]
Diagnosis condition
  • Ignition switch is "ON" position.
  • DCU supply voltage is 10 to 16 V.
  • At least 1 second has passed since the DCU was activated.
  • Urea tank remaining volume is 1.8 L or more.
  • 5 minutes or more have passed since the last time the ignition switch was turned "LOCK" (OFF) position.
  • Urea tank heater is activated.
Signal (terminal)
Urea tank heater
Threshold
  • The conductance of the urea tank heater is low (0.38 S or less).
or
  • The conductance of the urea tank heater is high (0.95 S or more).
NOTE:
Conductance: reciprocal of resistance, a value indicating the ease of current flow.
Diagnosis delay time
10 seconds
POSSIBLE CAUSE
  • Harness damage in urea pump module (urea tank heater) circuit or loose connector contact.
  • Harness damage in urea pump module (urea tank heater) earth circuit or loose connector contact.
  • Failed urea tank assembly [integrated with urea pump module (urea tank heater)].
FAIL-SAFE AND BACKUP FUNCTION
Heater does not work when urea is frozen. → Urea dosing is stopped.
DIAGNOSIS CODE CONFIRMATION PROCEDURE
1.Preconditioning
If "Diagnosis Code Confirmation Procedure" has been previously conducted, always turn the ignition switch to the "LOCK" (OFF) position and wait at least 180 seconds before conducting the next test.
2.Diagnosis code confirmation procedure
CAUTION:
To prevent damage to the M.U.T.-III SE, always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting the M.U.T.-III SE.
With M.U.T.-III SE
  1. 5 seconds or more later after the ignition switch has been in "ON" position
  2. Perform the following DCU actuator test item using M.U.T.-III SE (Refer to SPECIAL FUNCTION REFERENCE TABLE).
    • Item No. 2: Urea tank heater
  3. Perform "Self-diagnosis" of DCU using M.U.T.-III SE.
Is diagnosis code No. P202A-92 set?
YES
NO-1
To check malfunction symptom before repair: Check intermittent incident (Refer to General Information – General – Basic Inspection – Service Information for Electrical Incident – INTERMITTENT INCIDENT).
NO-2
Confirmation after repair: Inspection end.
BookmarkedToo many bookmarks.