ENGINE - ENGINE AND EMISSION CONTROL - EMISSION CONTROL<4N1> - UREA SCR SYSTEM<EURO 6B OR EURO 6C> - UREA SCR TROUBLESHOOTING - DIAGNOSIS CODE PROCEDURES - P204F-00 Reductant system bank 1
Diagnosis Procedure: P204F-00
N502631630000800ENG
1.Check other diagnosis code
Check whether the following diagnosis codes are set.
  • P204A-01: Reductant pressure sensor
  • P204A-11: Reductant pressure sensor
  • P204A-12: Reductant pressure sensor
  • P204A-1C: Reductant pressure sensor
  • P208A-92: Reductant pump A
  • P33FA-1C: Power supply error(urea pressure sensor)
  • P33FD-1E: Supply pump
  • U0666-00: Lost communication(reductant pressure sensor)
Is any diagnosis code set?
YES
Troubleshoot the diagnosis code (Refer to DIAGNOSIS CODE CHART).
NO
2.Diagnosis code recheck after erasing diagnosis code
Check if the diagnosis code is set again (Refer to DTC Description: P204F-00).
Is diagnosis code No. P204F-00 set?
YES
Replace the urea pump (integrated with urea pressure sensor and urea supply pump) (Refer to UREA TANK REMOVAL AND INSTALLATION). Then GO TO 3.
NO
Intermittent malfunction (Refer to General Information – General, Basic Inspection, Service Information for Electrical Incident INTERMITTENT INCIDENT).
3.Diagnosis code recheck after erasing diagnosis code
Check if the diagnosis code is set again (Refer to DTC Description: P204F-00).
Is diagnosis code No. P204F-00 set?
YES
Disconnect the DCU connector, then reconnect it securely.
NO
The check is end.