Diagnosis Code No. | M.U.T.-III SE Screen Item [Diagnosis item] | Diagnosis Code Detection Condition | |
P205A-1C | Urea Tank Temperature Sensor Circuit Range/Performance [Urea tank temperature sensor circuit range/performance] | Diagnosis condition |
|
Signal (terminal) | Urea temperature sensor | ||
Threshold | The difference between the urea tank temperature and the ambient temperature remains 30 °C or more for at least 5 seconds.
or
| ||