ENGINE - ENGINE AND EMISSION CONTROL - EMISSION CONTROL<4N1> - UREA SCR SYSTEM<EURO 6B OR EURO 6C> - UREA SCR TROUBLESHOOTING - DIAGNOSIS CODE PROCEDURES - P206A-11 Reductant quality sensor
DTC Description: P206A-11
N502631740000800ENG
DIAGNOSIS CODE DETECTION LOGIC
Diagnosis Code No.
M.U.T.-III SE Screen Item
[Diagnosis item]
Diagnosis Code Detection Condition
P206A-11
Reductant quality sensor
[Out of range check low error for urea concentration sensor]
Diagnosis condition
  • Ignition switch is "ON" position.
  • DCU supply voltage is 10 to 16 V.
  • At least 5 seconds has passed since the DCU was activated.
Signal (terminal)
Urea concentration sensor
Threshold
Urea quality sensor value is below –20 %.
Diagnosis delay time
2 seconds
POSSIBLE CAUSE
Failed urea tank assembly [integrated with urea pump module (TLC sensor)].
NOTE:
  • TLC sensor: Temperature/Level/Concentration sensor
  • The Urea pump module transmits the three TLC sensors' information on one SENT communication line.
FAIL-SAFE AND BACKUP FUNCTION
None.
DIAGNOSIS CODE CONFIRMATION PROCEDURE
1.Preconditioning
If "Diagnosis Code Confirmation Procedure" has been previously conducted, always turn the ignition switch to the "LOCK" (OFF) position and wait at least 180 seconds before conducting the next test.
2.Diagnosis code confirmation procedure
CAUTION:
To prevent damage to the M.U.T.-III SE, always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting the M.U.T.-III SE.
With M.U.T.-III SE
  1. 5 seconds or more later after the ignition switch has been in "ON" position
  2. Perform "Self-diagnosis" of DCU using M.U.T.-III SE.
Is diagnosis code No. P206A-11 set?
YES
NO-1
To check malfunction symptom before repair: Check intermittent incident (Refer to General Information – General – Basic Inspection – Service Information for Electrical Incident – INTERMITTENT INCIDENT).
NO-2
Confirmation after repair: Inspection end.