ENGINE - ENGINE AND EMISSION CONTROL - EMISSION CONTROL<4N1> - UREA SCR SYSTEM<EURO 6B OR EURO 6C> - UREA SCR TROUBLESHOOTING - DIAGNOSIS CODE PROCEDURES - P206A-1F Reductant quality sensor
DTC Description: P206A-1F
N502631800000K00ENG
DIAGNOSIS CODE DETECTION LOGIC
Diagnosis Code No.
M.U.T.-III SE Screen Item
[Diagnosis item]
Diagnosis Code Detection Condition
P206A-1F
Reductant quality sensor
[No echo error of urea concentration sensor]
Diagnosis condition
  • Ignition switch is "ON" position.
  • DCU supply voltage is 10 to 16 V.
  • At least 5 seconds has passed since the DCU was activated.
  • Urea tank temperature is –1 °C or more.
  • Urea tank is not frozen.
  • Urea tank volume is 1,602 g or more.
Signal (terminal)
Urea concentration sensor.
Threshold
Number of echoes received while vehicle is driven 20 km is less than 10 times.
Diagnosis delay time
Vehicle is driven 20.0 km.
POSSIBLE CAUSE
  • Failed urea tank assembly [integrated with urea pump module (TLC sensor)].
  • Failure due to non-AdBlue® supplementation (freezing, crystallisation, foaming)
  • Intermittent malfunction due to air bubble on the quality sensor
    Confirm following 1 and 2 with the customer to check the possiblity of air bubble. (Refer to Diagnosis Procedure: P206A-1F for the detail.)
    1. Confirm the recent usage condition with the customer: Did the vehicle experience any extreme driving conditions during last 100 km?
    2. Confirm with the customer when the vehicle last experienced an extreme driving condition: Has 12 hours or more passed since the vehicle last experienced an extreme driving condition?
NOTE:
  • TLC sensor: Temperature/Level/Concentration sensor
  • The Urea pump module transmits the three TLC sensors' information on one SENT communication line.
FAIL-SAFE AND BACKUP FUNCTION
None.
DIAGNOSIS CODE CONFIRMATION PROCEDURE
1.Preconditioning
If "Diagnosis Code Confirmation Procedure" has been previously conducted, always turn the ignition switch to the "LOCK" (OFF) position and wait at least 180 seconds before conducting the next test.
2.Diagnosis code confirmation procedure
CAUTION:
To prevent damage to the M.U.T.-III SE, always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting the M.U.T.-III SE.
With M.U.T.-III SE
  1. 5 seconds or more later after the ignition switch has been in "ON" position
  2. Perform "Self-diagnosis" of DCU using M.U.T.-III SE.
Is diagnosis code No. P206A-1F set?
YES
NO-1
To check malfunction symptom before repair: Check intermittent incident (Refer to General Information – General – Basic Inspection – Service Information for Electrical Incident – INTERMITTENT INCIDENT).
NO-2
Confirmation after repair: Inspection end.