2.Check short circuit to power supply between DCU and urea pump (urea supply pump) circuit
Disconnect DCU connector and urea pump connector.
Check the harness connector side.
Turn the ignition switch to the "ON" position.
Check voltage between DCU connector and body earth.
(+) | (–) | Voltage |
DCU |
Connector | Terminal |
A-129 | 11 | Body earth | 1 V or less |
33 |
Turn the ignition switch to the "LOCK" (OFF) position.
Check continuity between DCU connector.
(+) | (–) | Continuity |
DCU | DCU |
Connector | Terminal | Connector | Terminal |
A-129 | 11 | A-129 | 1 | No continuity |
3 |
5 |
66 |
89 |
33 | 1 |
3 |
5 |
66 |
89 |
Check harness wire and connector damage between DCU connector and urea pump connector.
DCU | Urea pump | Damage check |
Connector | Terminal | Connector | Terminal |
A-129 | 11 | G-54 | 5 | Good condition |
33 | 4 |
Are the check result normal?
YES
NO
Repair or replace the connector, or repair the damaged harness wire.
3.Diagnosis code recheck after erasing diagnosis code
Is diagnosis code No. P208A-12 set?
YES
Disconnect the DCU connector, then reconnect it securely.
NO
Intermittent malfunction (Refer to General Information – General – Basic Inspection – Service Information for Electrical Incident –
INTERMITTENT INCIDENT).