ENGINE - ENGINE AND EMISSION CONTROL - EMISSION CONTROL<4N1> - UREA SCR SYSTEM<EURO 6B OR EURO 6C> - UREA SCR TROUBLESHOOTING - DIAGNOSIS CODE PROCEDURES - P20B9-12 Reductant heater A
Diagnosis Procedure: P20B9-12
N502631990000900ENG
1.Check urea line tube heater
Check urea line tube heater (Refer to UREA LINE TUBE HEATER CHECK).
Is the check result normal?
YES
NO
Replace the urea line tube A and/or urea line tube B (Refer to UREA INJECTOR, UREA FEED TUBE REMOVAL AND INSTALLATION).
2.Check urea line tube heater earth circuit
  1. Disconnect urea heater tube connector.
  2. Check the harness side.
  3. Check continuity between urea heater tube connector and body earth.
    (+)
    (–)
    Continuity
    Urea heater tube
    Connector
    Terminal
    G-52
    1
    Body earth
    Continuity exists (2 Ω or less)
  4. Check harness wire and connector damage between urea heater tube connector and body earth.
    Urea heater tube
    Body earth point
    Damage check
    Connector
    Terminal
    No.
    G-52
    1
    21
    Good condition
Are the check result normal?
YES
NO
Repair or replace the connector, or repair the damaged harness wire.
3.Check between DCU and urea line tube heater circuit
  1. Disconnect DCU connector and urea heater tube connector.
  2. Check the harness side.
  3. Check continuity between DCU connector and urea heater tube connector.
    (+)
    (–)
    Continuity
    DCU
    Urea heater tube
    Connector
    Terminal
    Connector
    Terminal
    A-129
    6
    G-52
    2
    Continuity exists (2 Ω or less)
  4. Check continuity between DCU connector and body earth.
    (+)
    (–)
    Continuity
    DCU
    Connector
    Terminal
    A-129
    6
    Body earth
    No continuity
Are the check result normal?
YES
NO
Repair or replace the connector, or repair the damaged harness wire.
4.Check short circuit to power supply between DCU and urea line tube heater circuit
  1. Disconnect DCU connector and urea heater tube connector.
  2. Check the harness connector side.
  3. Turn the ignition switch to the "ON" position.
  4. Check voltage between DCU connector and body earth.
    (+)
    (–)
    Voltage
    DCU
    Connector
    Terminal
    A-129
    6
    Body earth
    0 V
  5. Turn the ignition switch to the "LOCK" (OFF) position.
  6. Check continuity between DCU connector.
    (+)
    (–)
    Continuity
    DCU
    DCU
    Connector
    Terminal
    Connector
    Terminal
    A-129
    6
    A-129
    1
    No continuity
    3
    5
    66
    89
Are the check result normal?
YES
NO
Repair or replace the connector, or repair the damaged harness wire.
5.Diagnosis code recheck after erasing diagnosis code
Check if the diagnosis code is set again (Refer to DTC Description: P20B9-12).
Is diagnosis code No. P20B9-12 set?
YES
Disconnect the DCU connector, then reconnect it securely.
NO
Intermittent malfunction (Refer to General Information – General – Basic Inspection – Service Information for Electrical Incident – INTERMITTENT INCIDENT).