ENGINE - ENGINE AND EMISSION CONTROL - EMISSION CONTROL<4N1> - UREA SCR SYSTEM<EURO 6B OR EURO 6C> - UREA SCR TROUBLESHOOTING - DIAGNOSIS CODE PROCEDURES - P20FA-11 Reductant pump B
Diagnosis Procedure: P20FA-11
N502632290000800ENG
1.Check urea pump (urea back flow pump)
Check urea pump (urea back flow pump) (Refer to UREA PUMP CHECK).
Is the check result normal?
YES
NO
Replace the pump (integrated with urea back flow pump) (Refer to UREA TANK DISASSEMBLY AND REASSEMBLY).
2.Check short circuit to earth between DCU and urea pump (urea back flow pump) circuit
  1. Disconnect DCU connector and urea pump connector.
  2. Check the harness side.
  3. Check continuity between DCU connector and body earth.
    (+)
    (–)
    Continuity
    DCU
    Connector
    Terminal
    A-129
    10
    Body earth
    No continuity
    32
  4. Also check harness damage for between DCU connector and urea pump connector.
  5. Check harness wire and connector damage between DCU connector and urea pump connector.
    DCU
    Urea pump
    Damage check
    Connector
    Terminal
    Connector
    Terminal
    A-129
    10
    G-54
    6
    Good condition
    32
    7
Is the check result normal?
YES
NO
Repair or replace the connector, or repair the damaged harness wire.
3.Diagnosis code recheck after erasing diagnosis code
Check if the diagnosis code is set again (Refer to DTC Description: P20FA-11).
Is diagnosis code No. P20FA-11 set?
YES
Disconnect the DCU connector, then reconnect it securely.
NO
Intermittent malfunction (Refer to General Information – General – Basic Inspection – Service Information for Electrical Incident – INTERMITTENT INCIDENT).