ENGINE - ENGINE AND EMISSION CONTROL - EMISSION CONTROL<4N1> - UREA SCR SYSTEM<EURO 6B OR EURO 6C> - UREA SCR TROUBLESHOOTING - DIAGNOSIS CODE PROCEDURES - P21CA-11 Reductant control module
DTC Description: P21CA-11
N502632400000800ENG
DIAGNOSIS CODE DETECTION LOGIC
Diagnosis Code No.
M.U.T.-III SE Screen Item
[Diagnosis item]
Diagnosis Code Detection Condition
P21CA-11
Reductant control module
[DCU supply voltage low]
Diagnosis condition
Ignition switch is "ON" position.
Signal (terminal)
–
Threshold
Battery power supply voltage is less than 8 V for 1 second.
Diagnosis delay time
1 second.
POSSIBLE CAUSE
  • Failed battery (poor charging/deteriorated/contaminated or loose terminals)
  • Open circuit or harness damage in DCU earth circuit or loose connector contact.
  • Harness damage or short circuit to earth in DCU power supply circuit or loose connector contact.
FAIL-SAFE AND BACKUP FUNCTION
Urea SCR system shutdown. → Urea dosing is stopped.
DIAGNOSIS CODE CONFIRMATION PROCEDURE
1.Preconditioning
If "Diagnosis Code Confirmation Procedure" has been previously conducted, always turn the ignition switch to the "LOCK" (OFF) position and wait at least 180 seconds before conducting the next test.
2.Diagnosis code confirmation procedure
CAUTION:
To prevent damage to the M.U.T.-III SE, always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting the M.U.T.-III SE.
With M.U.T.-III SE
  1. 5 seconds or more later after the ignition switch has been in "ON" position
  2. Perform "Self-diagnosis" of DCU using M.U.T.-III SE.
Is diagnosis code No. P21CA-11 set?
YES
NO-1
To check malfunction symptom before repair: Check intermittent incident (Refer to General Information – General – Basic Inspection – Service Information for Electrical Incident – INTERMITTENT INCIDENT).
NO-2
Confirmation after repair: Inspection end.
BookmarkedToo many bookmarks.
Please delete and bookmark again.