ENGINE - ENGINE AND EMISSION CONTROL - EMISSION CONTROL<4N1> - UREA SCR SYSTEM<EURO 6B OR EURO 6C> - UREA SCR TROUBLESHOOTING - DIAGNOSIS CODE PROCEDURES - P23AB-00 No.3 NOx Sensor Processor Performance
Diagnosis Procedure: P23AB-00
N502632680000700ENG
1.Diagnosis code recheck after erasing diagnosis code
Check if the diagnosis code is set again (Refer to DTC Description: P23AB-00).
Is diagnosis code No. P23AB-00 set?
YES
Replace the NOx sensor No. 3 (Refer to UREA SCR SYSTEM SENSORS REMOVAL AND INSTALLATION). Then GO TO 2.
NO
Intermittent malfunction (Refer to General Information – General – Basic Inspection – Service Information for Electrical Incident – INTERMITTENT INCIDENT).
2.Diagnosis code recheck after erasing diagnosis code
Check if the diagnosis code is set again (Refer to DTC Description: P23AB-00).
Is diagnosis code No. P23AB-00 set?
YES
Disconnect the DCU connector, then reconnect it securely.
NO
The check is end.
BookmarkedToo many bookmarks.
Please delete and bookmark again.