ENGINE - ENGINE AND EMISSION CONTROL - EMISSION CONTROL<4N1> - UREA SCR SYSTEM<EURO 6B OR EURO 6C> - UREA SCR TROUBLESHOOTING - DIAGNOSIS CODE PROCEDURES - P23BD-00 NOx sensor 3 bank 1
Diagnosis Procedure: P23BD-00
N502632830000100ENG
1.Check other system diagnosis code
Check whether the engine-ECU sets the diagnosis codes
Is any diagnosis code set?
YES
Troubleshoot the engine-ECU diagnosis code (Refer to Engine – Diesel Fuel – Troubleshooting – DIAGNOSIS CODE CHART).
NO
2.Diagnosis code recheck after erasing diagnosis code
Check if the diagnosis code is set again (Refer to DTC Description: P23BD-00).
Is diagnosis code No. P23BD-00 set?
YES
Replace the NOx sensor No. 3 (Refer to UREA SCR SYSTEM SENSORS REMOVAL AND INSTALLATION).
NO
Intermittent malfunction (Refer to General Information – General – Basic Inspection – Service Information for Electrical Incident – INTERMITTENT INCIDENT).