ENGINE - ENGINE AND EMISSION CONTROL - EMISSION CONTROL<4N1> - UREA SCR SYSTEM<EURO 6B OR EURO 6C> - UREA SCR TROUBLESHOOTING - DIAGNOSIS CODE PROCEDURES - P23C1-00 NOx sensor 3 bank 1
Diagnosis Procedure: P23C1-00
N502632890000C00ENG
1.NOx sensor No. 3 installation condition check
Check that the NOx sensor No. 3 is installed properly.
Is the check result normal?
YES
NO
Install the NOx sensor No. 3 properly. (Refer to UREA SCR SYSTEM SENSORS REMOVAL AND INSTALLATION). Then GO TO 2.
2.NOx sensor No. 3 function check
  1. Drive the vehicle until the status of the DCU data list item No. 28: NOx sensor 3 heater operating becomes "ON".
  2. Wait for 2 minutes or more with the vehicle in idling condition.
  3. Check that the display of the DCU data list item No. 89: O2 value(NOx sensor 3) changes when the accelerator pedal is depressed.
Is the check result normal?
YES
Intermittent malfunction (Refer to General Information – General – Basic Inspection – Service Information for Electrical Incident – INTERMITTENT INCIDENT).
NO
Replace the NOx sensor No. 3 (Refer to UREA SCR SYSTEM SENSORS REMOVAL AND INSTALLATION).
BookmarkedToo many bookmarks.