ENGINE - ENGINE AND EMISSION CONTROL - EMISSION CONTROL<4N1> - UREA SCR SYSTEM<EURO 6B OR EURO 6C> - UREA SCR TROUBLESHOOTING - DIAGNOSIS FUNCTION
UREA SCR SYSTEM WARNING SCREEN/INDICATOR, ENGINE WARNING LAMP
N502634630000D00ENG
Urea SCR System Warning Screen/Indicator, Engine Warning Lamp
When the abnormal condition occurs with respect to the items of urea SCR system shown in the table, the warning screen will display, the warning indicator will blink or the engine warning lamp will illuminate. The warning indicator flashes interlocking with the warning screen display. If the warning screen continues to be displayed on the information screen or if the engine warning lamp remains illuminated, check the (provisional) diagnosis code is set.
The warning screen is displayed once the system is determined to be defective, and it will continue to be displayed until the DCU determines that the system is normal. When the diagnosis code is erased by the M.U.T.-III SE, the engine warning lamp will go off, but the warning screen will not disappear.
In addition, when the warning screen is displayed, the countdown of the travelable distance starts at the same time. If you keep driving with the warning screen displayed until the travelable distance becomes 0 km, the engine restart is prohibited. If the ignition switch is "ON" position, driving can be continued even when the engine restart is prohibited. However, the engine cannot be started once the ignition switch is turned to the "LOCK" (OFF) position.
Flow chart of Urea SCR System Warning Screen/Indicator
NOTE:
When Urea SCR System Warning Screen/Indicator is indicated.
  • Check not only diagnosis code but also provisional diagnosis code as necessary (refer to flow chart).
  • Even if you erase the diagnosis code by M.U.T.-III SE, Urea System Warning Screen/Indicaotor will continue to indicate.
  • To cancel the Urea System Warning Screen/Indicaotor, please follow the trouble shoot of each diagnostic code.
Urea SCR System Warning Screen/Indicator, Engine Warning Lamp Inspection Items
Diagnosis code No.
Diagnosis item
Warning screen display/warning indicator blinking*1
Engine warning lamp illuminating
P0607-49
Control module
OFF
ON
P062F-00
Internal control module
OFF
ON
P06EA-00
No.1 NOx Sensor Processor Performance
OFF
ON
P2002-00
DPF Flow Resistance Below Limit
OFF
ON
P202A-11
Reductant tank heater
OFF
ON
P202A-12
Reductant tank heater
OFF
ON
P202A-13
Reductant tank heater
OFF
ON
P202A-92
Urea Tank Heater Control Circuit Performance
OFF
ON
P203A-01
Reductant level sensor A
ON
ON
P203A-11
Reductant level sensor A
OFF
ON
P203A-12
Reductant level sensor A
OFF
ON
P203A-1F
Reductant level sensor A
OFF
ON
P203A-2A
Reductant level sensor A
OFF
ON
P2047-11
Reductant injection valve unit 1 bank 1
ON
ON
P2047-12
Reductant injection valve unit 1 bank 1
ON
ON
P2047-13
Reductant injection valve unit 1 bank 1
ON
ON
P2047-73
Reductant injection valve unit 1 bank 1
ON
ON
P204A-01
Reductant pressure sensor
OFF
ON
P204A-11
Reductant pressure sensor
OFF
ON
P204A-12
Reductant pressure sensor
OFF
ON
P204A-1C
Reductant pressure sensor
OFF
ON
P204F-00
Reductant system bank 1
ON
OFF
P205A-11
Reductant tank temperature sensor
OFF
ON
P205A-12
Reductant tank temperature sensor
OFF
ON
P205A-1C
Urea Tank Temperature Sensor Circuit Range/Performance
OFF
ON
P206A-11
Reductant quality sensor
ON
ON
P206A-12
Reductant quality sensor
ON
ON
P206A-1F
Reductant quality sensor
ON <DCU software part number 237G7A001P *3>
ON
OFF <Except DCU software part number 237G7A001P *3>
P208A-11
Reductant pump A
ON
ON
P208A-12
Reductant pump A
ON
ON
P208A-13
Reductant pump A
ON
ON
P208A-92
Reductant pump A
OFF
OFF
P20B9-11
Reductant heater A
OFF
ON
P20B9-12
Reductant heater A
OFF
ON
P20B9-13
Reductant heater A
OFF
ON
P20B9-92
Urea Feed Tube Heater Control Circuit Performance
OFF
ON
P20E8-00
Reductant pressure
ON
ON
P20E9-00
Reductant pressure
ON
ON
P20EA-00*2
Reductant control module power relay
OFF
ON
P20EB-00
Reductant control module power relay
OFF
ON
P20EE-00
SCR Efficiency Below Threshold
OFF
ON
P20F4-00
Reductant consumption
ON
ON
P20F5-00
Reductant consumption
ON
ON
P20FA-11
Reductant pump B
ON
ON
P20FA-12
Reductant pump B
ON
ON
P20FA-13
Reductant pump B
ON
ON
P20FA-92
Reductant pump B
OFF
ON
P21CA-11
Reductant control module
ON
ON
P21CA-12
Reductant control module
ON
ON
P2200-01
NOx sensor 1 bank 1
OFF
ON
P2200-1C
No.1 NOx Sensor Circuit Range/Performance
OFF
ON
P2205-1C
No.1 NOx Sensor Heater Control Circuit Range/Performance
OFF
ON
P220A-00
NOx sensor 1 bank 1
OFF
ON
P225C-00
NOx sensor 1 bank 1
OFF
ON
P225D-00
NOx sensor 1 bank 1
OFF
ON
P22FB-00
NOx sensor 1 bank 1
OFF
ON
P23AB-00
No.3 NOx Sensor Processor Performance
OFF
ON
P23AC-01
NOx sensor 3 bank 1
OFF
ON
P23AC-1C
No.3 NOx Sensor Circuit Range/Performance
OFF
ON
P23B1-1C
No.3 NOx Sensor Heater Control Circuit Range/Performance
OFF
ON
P23B6-00
NOx sensor 3 bank 1
OFF
ON
P23BD-00
NOx sensor 3 bank 1
OFF
ON
P23BE-00
NOx sensor 3 bank 1
OFF
ON
P23C1-00
NOx sensor 3 bank 1
OFF
ON
P24AE-01
PM Sensor Circuit
OFF
ON
P24AE-12
PM Sensor Circuit High
OFF
ON
P24AE-92
PM Sensor Circuit Range/Performance
OFF
ON
P24B3-11
PM Sensor Heater Control Circuit Low
OFF
ON
P24B3-12
PM Sensor Heater Control Circuit High
OFF
ON
P24B3-1E
PM Sensor Heater Resistance
OFF
ON
P24C6-01
PM Sensor Temperature Circuit
OFF
ON
P24C6-11
PM Sensor Supply Voltage Circuit
OFF
ON
P24C6-92
PM Sensor Temperature Circuit Range/Performance
OFF
ON
P24DA-00
PM Sensor Exhaust Sample Error
OFF
ON
P2BA7-00
NOx exceedance(empty reagent tank)
OFF
OFF
P2BA9-00
NOx exceedance
ON
ON
P33FA-1C
Power supply error(urea pressure sensor)
OFF
ON
P33FB-1E
Urea injector 1
OFF
ON
P33FD-1E
Supply pump
OFF
ON
P33FE-1E
Backflow pump
OFF
ON
P33FF-1C
Power supply error(urea tank temperature sensor)
ON
ON
U0100-00
Lost communication(ECM/PCM A)
ON
ON
U029D-00
Lost communication(NOx sensor A)
OFF
ON
U02A1-00
Lost communication(NOx sensor C)
OFF
ON
U02A3-00
Lost communication with PM Sensor
OFF
ON
U0401-00
Invalid data(ECM/PCM A)
ON
ON
U04A4-00
Invalid Data Received from PM Sensor
OFF
ON
U059E-00
Invalid data(NOx sensor A)
OFF
ON
U05A4-00
PM sensor received invalid data from DCU
OFF
ON
U05A8-00
Invalid data(NOx sensor C)
OFF
ON
U0619-00
Lost communication(reductant level sensor A)
ON
ON
U0666-00
Lost communication(reductant pressure sensor)
OFF
ON
U1350-86
Engine communication(exhaust gas mass flow)
ON
ON
U1351-86
Engine communication(engine speed)
ON
ON
U1352-86
Engine communication(ambient temperature)
ON
ON
U1353-81
SENT communication error(urea tank temperature sensor)
ON
ON
U1354-86
Engine communication(air flow sensor)
OFF
ON
U1357-86
Engine communication(Accelerator pedal position)
OFF
ON
U1358-86
Engine communication(vehicle acceleration)
OFF
ON
U1359-86
Engine communication(EGR rate)
OFF
ON
U135A-88
Engine CAN communication error(Bus off)
ON
ON
U1360-86
Engine communication(EGR valve position)
OFF
ON
U1361-86
Engine communication(coolant temperature)
OFF
ON
U1362-86
Engine communication(Engine off time)
OFF
ON
U1363-86
Engine communication(Throttle valve position)
OFF
ON
U1365-86
Engine communication(vehicle speed)
OFF
ON
U1366-86
Engine communication(ambient pressure)
OFF
ON
U1368-86
Engine communication(air mass)
OFF
ON
U1373-86
Engine communication(upstream SCR temperature 1)
ON
ON
U1374-86
Engine communication(downstream SCR temperature 1)
ON
ON
U1378-86
Engine communication(NOx value)
ON
ON
U1379-86
Engine communication(differential pressure sensor)
OFF
ON
U1381-86
Engine communication(DPF regeneration request)
OFF
ON
U1382-86
Engine communication(fuel injection quantity)
OFF
ON
U1383-86
Engine communication(soot mass)
OFF
ON
U1384-86
Engine communication(fuel total injection quantity)
OFF
ON
U1385-86
Engine communication(soot mass)
OFF
ON
U1386-86
Engine communication(ECU off time)
OFF
ON
U1387-86
Engine communication(engine run time)
OFF
ON
U1388-86
Engine communication(engine run time)
OFF
ON
NOTE:
  • *1: The urea SCR system warning screen display ON, and the urea SCR system warning indicator blinking
  • After the DCU has detected a malfunction, the urea SCR system warning screen display/warning indicator illuminates when the same malfunction is re-detected 2 more drive cycles. However, for items marked with a "*2" in the diagnosis code number column, the urea SCR system warning screen display/warning indicator illuminates only on the first detection of the malfunction.
  • *3: The DCU software part number can be confirmed by following procedure.
    1. After turning the ignition switch to the "LOCK" (OFF) position, connect the M.U.T.-III SE to the diagnosis connector.
    2. Turn the ignition switch to the "ON" position.
    3. Select "UDCU" from System select screen of the M.U.T.-III SE.
    4. Select "Special Function" from UDCU screen.
    5. Select "ECU Information" from Special Function screen to confirm the DCU software part number.
BookmarkedToo many bookmarks.