ENGINE - ENGINE AND EMISSION CONTROL - EMISSION CONTROL<4N1> - UREA SCR SYSTEM<EURO 6B OR EURO 6C> - UREA SCR TROUBLESHOOTING - SYMPTOM PROCEDURES - Communication with no ECUs is possible (ENG-LOCAL CAN)
DIAGNOSIS PROCEDURE: Communication with no ECUs is possible (ENG-LOCAL CAN)
N502634720000100ENG
1.Check the ENG-LOCAL CAN for short to power supply. Voltage measurement at NOx sensor No. 1connector
CAUTION:
  • A digital multimeter should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  • The test wiring harness should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  1. Disconnect the NOx sensor No. 1 connector.
  2. Check the harness connector side.
  3. Connect the negative battery terminal.
  4. Turn the ignition switch to the "ON" position.
  5. Check voltage between NOx sensor No. 1 connector and body earth.
    (+)
    (–)
    Voltage
    NOx sensor No. 1
    Connector
    Terminal
    A-128
    4
    Body earth
    4.0 V or less
    3
  6. Turn the ignition switch to the "LOCK" (OFF) position and disconnect the negative battery terminal.
  7. Connect the NOx sensor No. 1 connector.
Are the check result normal?
YES <Voltage is 4.0 V or less in both terminals>
NO <Voltage is more than 4.0 V in either terminals>
Check inspection procedure 2: Diagnose shorts in the power supply to ENG-LOCAL CAN (Refer to DESCRIPTION: Diagnose shorts in the power supply to ENG-LOCAL CAN.).
2.Check the ENG-LOCAL CAN for short to earth. Resistance measurement at NOx sensor No. 1 connector
CAUTION:
  • A digital multimeter should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  • The test wiring harness should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  • When measuring the resistance, disconnect the negative battery terminal (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  1. Turn the ignition switch to the "LOCK" (OFF) position.
  2. Ensure that the negative battery terminal is disconnected.
  3. Disconnect the NOx sensor No. 1 connector.
  4. Check the harness connector side.
  5. Check resistance between NOx sensor No. 1 connector and body earth.
    (+)
    (–)
    Resistance
    NOx sensor No. 1
    Connector
    Terminal
    A-128
    4
    Body earth
    1 kΩ or more
    3
  6. Connect the NOx sensor No. 1 connector.
Are the check result normal?
YES <Resistance value is 1 kΩ or more in both terminals>
NO <Resistance value is less than 1 kΩ in either terminals>
Check inspection procedure 3: Diagnose shorts in the earth to ENG-LOCAL CAN (Refer to DESCRIPTION: Diagnose shorts in the earth to ENG-LOCAL CAN.).
3.Check the ENG-LOCAL CAN for short to each other. Resistance measurement at NOx sensor No. 1 connector
CAUTION:
  • A digital multimeter should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  • The test wiring harness should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  • When measuring the resistance, disconnect the negative battery terminal (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  1. Turn the ignition switch to the "LOCK" (OFF) position.
  2. Ensure that the negative battery terminal is disconnected.
  3. Disconnect the NOx sensor No. 1 connector.
  4. Check the harness connector side.
  5. Check resistance between NOx sensor No. 1 connector terminals.
    NOx sensor No. 1
    NOx sensor No. 1
    Resistance
    Connector
    Terminal
    Connector
    Terminal
    A-128
    4
    A-128
    3
    60 ± 10 Ω
  6. Connect the NOx sensor No. 1 connector.
Is the check result normal?
YES
NO <Resistance value is less than 60 ± 10 Ω>
Check inspection procedure 4: Diagnose shorts between CAN_H and L line (ENG-LOCAL CAN) (Refer to DESCRIPTION: Diagnose shorts between CAN_H and L lines (ENG-LOCAL CAN)).
4.Check the NOx sensor No. 1 for short to earth. Resistance measurement at joint connector (CAN2)
CAUTION:
  • A digital multimeter should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  • The test wiring harness should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  • When measuring the resistance, disconnect the negative battery terminal (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  1. Ensure that the negative battery terminal is disconnected.
  2. Disconnect the joint connector (CAN2) connector.
  3. Check the harness connector side.
  4. Check resistance between joint connector (CAN2) connector and body earth.
    <LHD>
    (+)
    (–)
    Resistance
    Joint connector (CAN2)
    Connector
    Terminal
    A-105
    4
    Body earth
    1 kΩ or more
    15
    <RHD>
    (+)
    (–)
    Resistance
    Joint connector (CAN2)
    Connector
    Terminal
    A-105
    2.
    Body earth
    1 kΩ or more
    13
  5. Connect the joint connector (CAN2) connector.
Are the check result normal?
YES <Resistance value is 1 kΩ or more in both terminals>
NO <Resistance value is less than 1 kΩ in either terminals>
Check the NOx sensor No. 1 connector, and repair if necessary. If the NOx sensor No. 1 connector is in good condition, replace the NOx sensor No. 1 (Refer to UREA SCR SYSTEM SENSORS REMOVAL AND INSTALLATION).
5.Check the NOx sensor No. 1 for short to power supply. Voltage measurement at joint connector (CAN2)
CAUTION:
  • A digital multimeter should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  • The test wiring harness should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  1. Disconnect the joint connector (CAN2) connector.
  2. Check the harness connector side.
  3. Connect the negative battery terminal.
  4. Turn the ignition switch to the "ON" position.
  5. Check voltage between joint connector (CAN2) connector and body earth.
    <LHD>
    (+)
    (–)
    Voltage
    Joint connector (CAN2)
    Connector
    Terminal
    A-105
    4
    Body earth
    4.0 V or less
    15
    <RHD>
    (+)
    (–)
    Voltage
    Joint connector (CAN2)
    Connector
    Terminal
    A-105
    2
    Body earth
    4.0 V or less
    13
  6. Turn the ignition switch to the "LOCK" (OFF) position and disconnect the negative battery terminal.
  7. Connect the joint connector (CAN2) connector.
Are the check result normal?
YES <Voltage is 4.0 V or less in both terminals>
NO <Voltage is more than 4.0 V in either terminals>
Check the NOx sensor No. 1 connector, and repair if necessary. If the NOx sensor No. 1 connector is in good condition, replace the NOx sensor No. 1 (Refer to UREA SCR SYSTEM SENSORS REMOVAL AND INSTALLATION).
6.Check the NOx sensor No. 1 for short to each other. Resistance measurement at NOx sensor No. 1 connector
CAUTION:
A digital multimeter should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  1. Disconnect the NOx sensor No. 1 connector.
  2. Check the NOx sensor No. 1 connector side.
  3. Check resistance between NOx sensor No. 1 connector terminals.
    NOx sensor No. 1
    NOx sensor No. 1
    Resistance
    Connector
    Terminal
    Connector
    Terminal
    A-128
    4
    A-128
    3
    1 kΩ or more
  4. Connect the NOx sensor No. 1 connector.
Is the check result normal?
YES
Check inspection procedure 5: DCU power supply system (Communication between M.U.T.-III SE and DCU is not possible) (Refer to DESCRIPTION: DCU power supply system (Communication between M.U.T.-IIISE and DCU is not possible)).
NO
Check the NOx sensor No. 1 connector, and repair if necessary. If the NOx sensor No. 1 connector is in good condition, replace the NOx sensor No. 1 (Refer to UREA SCR SYSTEM SENSORS REMOVAL AND INSTALLATION).
BookmarkedToo many bookmarks.
Please delete and bookmark again.