1.Check the ENG-LOCAL CAN for short to power supply. Voltage measurement at NOx sensor No. 1connector
CAUTION:
A digital multimeter should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) –
SERVICE PRECAUTIONS).
The test wiring harness should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) –
SERVICE PRECAUTIONS).
Disconnect the NOx sensor No. 1 connector.
Check the harness connector side.
Connect the negative battery terminal.
Turn the ignition switch to the "ON" position.
Check voltage between NOx sensor No. 1 connector and body earth.
(+) | (–) | Voltage |
NOx sensor No. 1 |
Connector | Terminal |
A-128 | 4 | Body earth | 4.0 V or less |
3 |
Turn the ignition switch to the "LOCK" (OFF) position and disconnect the negative battery terminal.
Connect the NOx sensor No. 1 connector.
Are the check result normal?
YES <Voltage is 4.0 V or less in both terminals>
NO <Voltage is more than 4.0 V in either terminals>
2.Check the ENG-LOCAL CAN for short to earth. Resistance measurement at NOx sensor No. 1 connector
CAUTION:
A digital multimeter should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) –
SERVICE PRECAUTIONS).
The test wiring harness should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) –
SERVICE PRECAUTIONS).
When measuring the resistance, disconnect the negative battery terminal (For details refer to Electrical & Power Control – Controller Area Network (CAN) –
SERVICE PRECAUTIONS).
Turn the ignition switch to the "LOCK" (OFF) position.
Ensure that the negative battery terminal is disconnected.
Disconnect the NOx sensor No. 1 connector.
Check the harness connector side.
Check resistance between NOx sensor No. 1 connector and body earth.
(+) | (–) | Resistance |
NOx sensor No. 1 |
Connector | Terminal |
A-128 | 4 | Body earth | 1 kΩ or more |
3 |
Connect the NOx sensor No. 1 connector.
Are the check result normal?
YES <Resistance value is 1 kΩ or more in both terminals>
NO <Resistance value is less than 1 kΩ in either terminals>
3.Check the ENG-LOCAL CAN for short to each other. Resistance measurement at NOx sensor No. 1 connector
CAUTION:
A digital multimeter should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) –
SERVICE PRECAUTIONS).
The test wiring harness should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) –
SERVICE PRECAUTIONS).
When measuring the resistance, disconnect the negative battery terminal (For details refer to Electrical & Power Control – Controller Area Network (CAN) –
SERVICE PRECAUTIONS).
Turn the ignition switch to the "LOCK" (OFF) position.
Ensure that the negative battery terminal is disconnected.
Disconnect the NOx sensor No. 1 connector.
Check the harness connector side.
Check resistance between NOx sensor No. 1 connector terminals.
NOx sensor No. 1 | NOx sensor No. 1 | Resistance |
Connector | Terminal | Connector | Terminal |
A-128 | 4 | A-128 | 3 | 60 ± 10 Ω |
Connect the NOx sensor No. 1 connector.
Is the check result normal?
YES
NO <Resistance value is less than 60 ± 10 Ω>
4.Check the NOx sensor No. 1 for short to earth. Resistance measurement at joint connector (CAN2)
CAUTION:
A digital multimeter should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) –
SERVICE PRECAUTIONS).
The test wiring harness should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) –
SERVICE PRECAUTIONS).
When measuring the resistance, disconnect the negative battery terminal (For details refer to Electrical & Power Control – Controller Area Network (CAN) –
SERVICE PRECAUTIONS).
Ensure that the negative battery terminal is disconnected.
Disconnect the joint connector (CAN2) connector.
Check the harness connector side.
Check resistance between joint connector (CAN2) connector and body earth.
<LHD>
(+) | (–) | Resistance |
Joint connector (CAN2) |
Connector | Terminal |
A-105 | 4 | Body earth | 1 kΩ or more |
15 |
<RHD>
(+) | (–) | Resistance |
Joint connector (CAN2) |
Connector | Terminal |
A-105 | 2. | Body earth | 1 kΩ or more |
13 |
Connect the joint connector (CAN2) connector.
Are the check result normal?
YES <Resistance value is 1 kΩ or more in both terminals>
NO <Resistance value is less than 1 kΩ in either terminals>
5.Check the NOx sensor No. 1 for short to power supply. Voltage measurement at joint connector (CAN2)
CAUTION:
A digital multimeter should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) –
SERVICE PRECAUTIONS).
The test wiring harness should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) –
SERVICE PRECAUTIONS).
Disconnect the joint connector (CAN2) connector.
Check the harness connector side.
Connect the negative battery terminal.
Turn the ignition switch to the "ON" position.
Check voltage between joint connector (CAN2) connector and body earth.
<LHD>
(+) | (–) | Voltage |
Joint connector (CAN2) |
Connector | Terminal |
A-105 | 4 | Body earth | 4.0 V or less |
15 |
<RHD>
(+) | (–) | Voltage |
Joint connector (CAN2) |
Connector | Terminal |
A-105 | 2 | Body earth | 4.0 V or less |
13 |
Turn the ignition switch to the "LOCK" (OFF) position and disconnect the negative battery terminal.
Connect the joint connector (CAN2) connector.
Are the check result normal?
YES <Voltage is 4.0 V or less in both terminals>
NO <Voltage is more than 4.0 V in either terminals>
6.Check the NOx sensor No. 1 for short to each other. Resistance measurement at NOx sensor No. 1 connector
CAUTION:
A digital multimeter should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) –
SERVICE PRECAUTIONS).
Disconnect the NOx sensor No. 1 connector.
Check the NOx sensor No. 1 connector side.
Check resistance between NOx sensor No. 1 connector terminals.
NOx sensor No. 1 | NOx sensor No. 1 | Resistance |
Connector | Terminal | Connector | Terminal |
A-128 | 4 | A-128 | 3 | 1 kΩ or more |
Connect the NOx sensor No. 1 connector.
Is the check result normal?
YES
NO