ENGINE - ENGINE AND EMISSION CONTROL - EMISSION CONTROL<4N1> - UREA SCR SYSTEM<EURO 6B OR EURO 6C> - UREA SCR TROUBLESHOOTING - SYMPTOM PROCEDURES - Diagnose shorts in the power supply to ENG-LOCAL CAN
DIAGNOSIS PROCEDURE: Diagnose shorts in the power supply to ENG-LOCAL CAN
N502634750000800ENG
1.Check the ENG-LOCAL CAN. Voltage measurement at DCU connector
CAUTION:
  • A digital multimeter should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  • The test wiring harness should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
NOTE:
This inspection allows you to check that there is a short to power supply in either CAN_H line or CAN_L line. Thus, in the following steps, check the ENG-LOCAL CAN that is defective.
  1. Disconnect engine-ECU connector and DCU connector.
  2. Check the harness connector side.
  3. Connect the negative battery terminal.
  4. Turn the ignition switch to the "ON" position.
  5. Check voltage between DCU connector and body earth.
    (+)
    (–)
    Voltage
    DCU
    Connector
    Terminal
    A-129
    87
    Body earth
    4.0 V or less
    65
  6. Turn the ignition switch to the "LOCK" (OFF) position and disconnect the negative battery terminal.
  7. Connect engine-ECU connector and DCU connector.
Are the check result normal?
YES <Voltage is 4.0 V or less in both terminals>
NO <Voltage is more than 4.0 V in either terminals>
2.Check the ENG-LOCAL CAN between joint connector and DCU. Voltage measurement at joint connector
CAUTION:
  • A digital multimeter should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  • The test wiring harness should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  • Strictly observe the specified wiring harness repair procedure (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  1. Disconnect joint connector connector.
  2. Check the harness connector side.
  3. Connect the negative battery terminal.
  4. Turn the ignition switch to the "ON" position.
  5. Check voltage between joint connector connector and body earth.
    (+)
    (–)
    Voltage
    Joint connector (24)
    Connector
    Terminal
    G-46
    8
    Body earth
    4.0 V or less
    5
  6. Turn the ignition switch to the "LOCK" (OFF) position and disconnect the negative battery terminal.
  7. Connect joint connector connector.
Are the check result normal?
YES <Voltage is 4.0 V or less in both terminals>
NO <Voltage is more than 4.0 V in either terminals>
Repair the wiring harness between joint connector connector and DCU connector.
3.Check the ENG-LOCAL CAN between joint connector and NOx sensor No. 3. Voltage measurement at joint connector
CAUTION:
  • A digital multimeter should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  • The test wiring harness should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  1. Disconnect joint connector connector.
  2. Check the harness connector side.
  3. Connect the negative battery terminal.
  4. Turn the ignition switch to the "ON" position.
  5. Check voltage between joint connector connector and body earth.
    (+)
    (–)
    Voltage
    Joint connector (24)
    Connector
    Terminal
    G-46
    3
    Body earth
    4.0 V or less
    2
  6. Turn the ignition switch to the "LOCK" (OFF) position and disconnect the negative battery terminal.
  7. Connect joint connector connector.
Are the check result normal?
YES <Voltage is 4.0 V or less in both terminals>
NO <Voltage is more than 4.0 V in either terminals>
4.Diagnose the ENG-LOCAL CAN (NOx sensor No. 3 connector disconnected)
CAUTION:
Strictly observe the specified wiring harness repair procedure (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  1. Disconnect NOx sensor No. 3 connector and read all diagnosis with M.U.T.-III SE.
  2. Confirm that all diagnosis reading result of the DCU is "NC".
Is all diagnosis reading result of the DCU "NC"?
YES
Repair the wiring harness between joint connector connector and NOx sensor No. 3 connector.
NO
Check the NOx sensor No. 3 connector, and repair if necessary. If the NOx sensor No. 3 connector is in good condition, GO TO 5.
5.Diagnose the ENG-LOCAL CAN
  1. Read all diagnosis with M.U.T.-III SE.
  2. Confirm that all diagnosis reading result of the DCU is normal (other than "NC").
Is the check result normal?
YES
Intermittent malfunction (Refer to General Information – General – Basic Inspection – Service Information for Electrical Incident – INTERMITTENT INCIDENT).
NO
Check the NOx sensor No. 3 connector, and repair if necessary. If the NOx sensor No. 3 connector is in good condition, replace the NOx sensor No. 3 (Refer to UREA SCR SYSTEM SENSORS REMOVAL AND INSTALLATION).
6.Check the ENG-LOCAL CAN between joint connector and PM sensor. Voltage measurement at joint connector
CAUTION:
  • A digital multimeter should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  • The test wiring harness should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  1. Disconnect joint connector connector.
  2. Check the harness connector side.
  3. Connect the negative battery terminal.
  4. Turn the ignition switch to the "ON" position.
  5. Check voltage between joint connector connector and body earth.
    (+)
    (–)
    Voltage
    Joint connector (24)
    Connector
    Terminal
    G-46
    4
    Body earth
    4.0 V or less
    1
  6. Turn the ignition switch to the "LOCK" (OFF) position and disconnect the negative battery terminal.
  7. Connect joint connector connector.
Are the check result normal?
YES <Voltage is 4.0 V or less in both terminals>
NO <Voltage is more than 4.0 V in either terminals>
7.Diagnose the ENG-LOCAL CAN (PM sensor connector disconnected)
CAUTION:
Strictly observe the specified wiring harness repair procedure (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  1. Disconnect PM sensor connector and read all diagnosis with M.U.T.-III SE.
  2. Confirm that all diagnosis reading result of the DCU is "NC".
Is all diagnosis reading result of the DCU "NC"?
YES
Repair the wiring harness between joint connector connector and PM sensor connector.
NO
Check the PM sensor connector, and repair if necessary. If the PM sensor connector is in good condition, GO TO 8.
8.Diagnose the ENG-LOCAL CAN
  1. Read all diagnosis with M.U.T.-III SE.
  2. Confirm that all diagnosis reading result of the DCU is normal (other than "NC").
Is the check result normal?
YES
Intermittent malfunction (Refer to General Information – General – Basic Inspection – Service Information for Electrical Incident – INTERMITTENT INCIDENT).
NO
Check the PM sensor connector, and repair if necessary. If the PM sensor connector is in good condition, replace the PM sensor (Refer to UREA SCR SYSTEM SENSORS REMOVAL AND INSTALLATION).
9.Check the ENG-LOCAL CAN between joint connector (CAN2) and joint connector. Voltage measurement at joint connector (CAN2)
CAUTION:
  • A digital multimeter should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  • The test wiring harness should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  1. Disconnect joint connector (CAN2) connector.
  2. Check the harness connector side.
  3. Connect the negative battery terminal.
  4. Turn the ignition switch to the "ON" position.
  5. Check voltage between joint connector (CAN2) connector and body earth.
    <LHD>
    (+)
    (–)
    Voltage
    Joint connector (CAN2)
    Connector
    Terminal
    A-105
    5
    Body earth
    4.0 V or less
    16
    <RHD>
    (+)
    (–)
    Voltage
    Joint connector (CAN2)
    Connector
    Terminal
    A-105
    1
    Body earth
    4.0 V or less
    12
  6. Turn the ignition switch to the "LOCK" (OFF) position and disconnect the negative battery terminal.
  7. Connect joint connector (CAN2) connector.
Are the check result normal?
YES <Voltage is 4.0 V or less in both terminals>
NO <Voltage is more than 4.0 V in either terminals>
10.Diagnose the ENG-LOCAL CAN [joint connector (CAN2) connector disconnected]
CAUTION:
Strictly observe the specified wiring harness repair procedure (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  1. Disconnect joint connector (CAN2) connector and read all diagnosis with M.U.T.-III SE.
  2. Confirm that all diagnosis reading result of the DCU is "NC".
Is all diagnosis reading result of the DCU "NC"?
YES
Repair the wiring harness between joint connector (CAN2) connector and joint connector connector.
NO
Check the joint connector, and repair if necessary. If the joint connector is in good condition, GO TO 11.
11.Diagnose the ENG-LOCAL CAN
  1. Read all diagnosis with M.U.T.-III SE.
  2. Confirm that all diagnosis reading result of the DCU is normal (other than "NC").
Is the check result normal?
YES
Intermittent malfunction (Refer to General Information – General – Basic Inspection – Service Information for Electrical Incident – INTERMITTENT INCIDENT).
NO
Check the joint connector connector, and repair if necessary.
12.Check the ENG-LOCAL CAN between joint connector (CAN2) and NOx sensor No. 1. Voltage measurement at joint connector (CAN2)
CAUTION:
  • A digital multimeter should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  • The test wiring harness should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  1. Disconnect joint connector (CAN2) connector.
  2. Check the harness connector side.
  3. Connect the negative battery terminal.
  4. Turn the ignition switch to the "ON" position.
  5. Check voltage between joint connector (CAN2) connector and body earth.
    <LHD>
    (+)
    (–)
    Voltage
    Joint connector (CAN2)
    Connector
    Terminal
    A-105
    3
    Body earth
    4.0 V or less
    15
    <RHD>
    (+)
    (–)
    Voltage
    Joint connector (CAN2)
    Connector
    Terminal
    A-105
    2
    Body earth
    4.0 V or less
    13
  6. Turn the ignition switch to the "LOCK" (OFF) position and disconnect the negative battery terminal.
  7. Connect joint connector (CAN2) connector.
Are the check result normal?
YES <Voltage is 4.0 V or less in both terminals>
NO <Voltage is more than 4.0 V in either terminals>
13.Diagnose the ENG-LOCAL CAN (NOx sensor No. 1 connector disconnected)
CAUTION:
Strictly observe the specified wiring harness repair procedure (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  1. Disconnect NOx sensor No. 1 connector and read all diagnosis with M.U.T.-III SE.
  2. Confirm that all diagnosis reading result of the DCU is "NC".
Is all diagnosis reading result of the DCU "NC"?
YES
Repair the wiring harness between joint connector (CAN2) connector and NOx sensor No. 1 connector.
NO
Check the NOx sensor No. 1 connector, and repair if necessary. If the NOx sensor No. 1 connector is in good condition, GO TO 14.
14.Diagnose the ENG-LOCAL CAN
  1. Read all diagnosis with M.U.T.-III SE.
  2. Confirm that all diagnosis reading result of the DCU is normal (other than "NC").
Is the check result normal?
YES
Intermittent malfunction (Refer to General Information – General – Basic Inspection – Service Information for Electrical Incident – INTERMITTENT INCIDENT).
NO
Check the NOx sensor No. 1 connector, and repair if necessary. If the NOx sensor No. 1 connector is in good condition, replace the NOx sensor No. 1 (Refer to UREA SCR SYSTEM SENSORS REMOVAL AND INSTALLATION).
15.Check the ENG-LOCAL CAN between joint connector (CAN2) and the engine-ECU. Voltage measurement at joint connector (CAN2).
CAUTION:
  • A digital multimeter should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  • The test wiring harness should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  • Strictly observe the specified wiring harness repair procedure (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  1. Disconnect joint connector (CAN2) connector.
  2. Check the harness connector side.
  3. Connect the negative battery terminal.
  4. Turn the ignition switch to the "ON" position.
  5. Check voltage between joint connector (CAN2) connector and body earth.
    (+)
    (–)
    Voltage
    Joint connector (CAN2)
    Connector
    Terminal
    A-105
    3
    Body earth
    4.0 V or less
    14
  6. Turn the ignition switch to the "LOCK" (OFF) position and disconnect the negative battery terminal.
  7. Connect joint connector (CAN2) connector.
Are the check result normal?
YES <Voltage is 4.0 V or less in both terminals>
Repair the joint connector (CAN2).
NO <Voltage is more than 4.0 V in either terminals>
Repair the wiring harness between joint connector (CAN2) connector and engine-ECU connector.
16.Diagnose the ENG-LOCAL CAN (DCU connector disconnected)
  • Disconnect DCU connector and read all diagnosis with M.U.T.-III SE.
  • Confirm that all diagnosis reading result of the DCU is "NC".
Is all diagnosis reading result of the DCU "NC"?
YES
NO
Check the DCU connector, and repair if necessary. If the DCU connector is in good condition, GO TO 17.
17.Diagnose the ENG-LOCAL CAN
  • Read all diagnosis with M.U.T.-III SE.
  • Confirm that all diagnosis reading result of the DCU is normal (other than "NC").
Is the check result normal?
YES
Intermittent malfunction (Refer to General Information – General – Basic Inspection – Service Information for Electrical Incident – INTERMITTENT INCIDENT).
NO
Disconnect the DCU connector, then reconnect it securely.
18.Diagnose the ENG-LOCAL CAN
  • Read all diagnosis with M.U.T.-III SE.
  • Confirm that all diagnosis reading result of the DCU is normal (other than "NC").
Is the check result normal?
YES
Intermittent malfunction (Refer to General Information – General – Basic Inspection – Service Information for Electrical Incident – INTERMITTENT INCIDENT).
NO
Replace the engine-ECU (Refer to Engine – Diesel Fuel <4N1> – Engine-ECU – ENGINE-ECU REMOVAL AND INSTALLATION).
BookmarkedToo many bookmarks.
Please delete and bookmark again.