ENGINE - ENGINE AND EMISSION CONTROL - EMISSION CONTROL<4N1> - UREA SCR SYSTEM<EURO 6B OR EURO 6C> - UREA SCR TROUBLESHOOTING - SYMPTOM PROCEDURES - Diagnose shorts in the earth to ENG-LOCAL CAN
DIAGNOSIS PROCEDURE: Diagnose shorts in the earth to ENG-LOCAL CAN
N502634780000800ENG
1.Check the ENG-LOCAL CAN. Resistance measurement at DCU connector
CAUTION:
  • A digital multimeter should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  • The test wiring harness should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  • When measuring the resistance, disconnect the negative battery terminal (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
NOTE:
This inspection allows you to check that there is a short to earth in either CAN_H line or CAN_L line. Thus, in the following steps, check the ENG-LOCAL CAN that is defective.
  1. Ensure that the negative battery terminal is disconnected.
  2. Disconnect engine-ECU connector and DCU connector.
  3. Check the harness connector side.
  4. Check resistance between DCU connector and body earth.
    (+)
    (–)
    Resistance
    DCU
    Connector
    Terminal
    A-129
    87
    Body earth
    1 kΩ or more
    65
  5. Connect engine-ECU connector and DCU connector.
Are the check result normal?
YES <Resistance value is 1 kΩ or more in both terminals>
NO <Resistance value is less than 1 kΩ in either terminals>
2.Check the ENG-LOCAL CAN between joint connector and DCU. Resistance measurement at joint connector
CAUTION:
  • A digital multimeter should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  • The test wiring harness should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  • When measuring the resistance, disconnect the negative battery terminal (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  • Strictly observe the specified wiring harness repair procedure (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  1. Ensure that the negative battery terminal is disconnected.
  2. Disconnect joint connector connector.
  3. Check the harness connector side.
  4. Check resistance between joint connector connector and body earth.
    (+)
    (–)
    Resistance
    Joint connector (24)
    Connector
    Terminal
    G-46
    8
    Body earth
    1 kΩ or more
    5
  5. Connect joint connector connector.
Are the check result normal?
YES <Resistance value is 1 kΩ or more in both terminals>
NO <Resistance value is less than 1 kΩ in either terminals>
Repair the wiring harness between joint connector connector and DCU connector.
3.Check the ENG-LOCAL CAN between joint connector and NOx sensor No. 3. Resistance measurement at joint connector
CAUTION:
  • A digital multimeter should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  • The test wiring harness should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  • When measuring the resistance, disconnect the negative battery terminal (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  1. Ensure that the negative battery terminal is disconnected.
  2. Disconnect joint connector connector.
  3. Check the harness connector side.
  4. Check resistance between joint connector connector and body earth.
    (+)
    (–)
    Resistance
    Joint connector (24)
    Connector
    Terminal
    G-46
    3
    Body earth
    1 kΩ or more
    2
  5. Connect joint connector connector.
Are the check result normal?
YES <Resistance value is 1 kΩ or more in both terminals>
NO <Resistance value is less than 1 kΩ in either terminals>
4.Diagnose the ENG-LOCAL CAN (NOx sensor No. 3 connector disconnected)
CAUTION:
Strictly observe the specified wiring harness repair procedure (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  1. Disconnect NOx sensor No. 3 connector and read all diagnosis with M.U.T.-III SE.
  2. Confirm that all diagnosis reading result of the DCU is "NC".
Is all diagnosis reading result of the DCU "NC"?
YES
Repair the wiring harness between joint connector connector and NOx sensor No. 3 connector.
NO
Check the NOx sensor No. 3 connector, and repair if necessary. If the NOx sensor No. 3 connector is in good condition, GO TO 5.
5.Diagnose the ENG-LOCAL CAN
  1. Read all diagnosis with M.U.T.-III SE.
  2. Confirm that all diagnosis reading result of the DCU is normal (other than "NC").
Is the check result normal?
YES
Intermittent malfunction (Refer to General Information – General – Basic Inspection – Service Information for Electrical Incident – INTERMITTENT INCIDENT).
NO
Check the NOx sensor No. 3 connector, and repair if necessary. If the NOx sensor No. 3 connector is in good condition, replace the NOx sensor No. 3 (Refer to UREA SCR SYSTEM SENSORS REMOVAL AND INSTALLATION).
6.Check the ENG-LOCAL CAN between joint connector and PM sensor. Resistance measurement at joint connector
CAUTION:
  • A digital multimeter should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  • The test wiring harness should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  • When measuring the resistance, disconnect the negative battery terminal (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  1. Ensure that the negative battery terminal is disconnected.
  2. Disconnect joint connector connector.
  3. Check the harness connector side.
  4. Check resistance between joint connector connector and body earth.
    (+)
    (–)
    Resistance
    Joint connector (24)
    Connector
    Terminal
    G-46
    4
    Body earth
    1 kΩ or more
    1
  5. Connect joint connector connector.
Are the check result normal?
YES <Resistance value is 1 kΩ or more in both terminals>
NO <Resistance value is less than 1 kΩ in either terminals>
7.Diagnose the ENG-LOCAL CAN (PM sensor connector disconnected)
CAUTION:
Strictly observe the specified wiring harness repair procedure (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  1. Disconnect PM sensor connector and read all diagnosis with M.U.T.-III SE.
  2. Confirm that all diagnosis reading result of the DCU is "NC".
Is all diagnosis reading result of the DCU "NC"?
YES
Repair the wiring harness between joint connector connector and PM sensor connector.
NO
Check the PM sensor connector, and repair if necessary. If the PM sensor connector is in good condition, GO TO 8.
8.Diagnose the ENG-LOCAL CAN
  1. Read all diagnosis with M.U.T.-III SE.
  2. Confirm that all diagnosis reading result of the DCU is normal (other than "NC").
Is the check result normal?
YES
Intermittent malfunction (Refer to General Information – General – Basic Inspection – Service Information for Electrical Incident – INTERMITTENT INCIDENT).
NO
Check the PM sensor connector, and repair if necessary. If the PM sensor connector is in good condition, replace the PM sensor (Refer to UREA SCR SYSTEM SENSORS REMOVAL AND INSTALLATION).
9.Check the ENG-LOCAL CAN between joint connector (CAN2) and joint connector. Resistance measurement at joint connector (CAN2)
CAUTION:
  • A digital multimeter should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  • The test wiring harness should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  • When measuring the resistance, disconnect the negative battery terminal (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  1. Ensure that the negative battery terminal is disconnected.
  2. Disconnect joint connector (CAN2) connector.
  3. Check the harness connector side.
  4. Check resistance between joint connector (CAN2) connector and body earth.
    <LHD>
    (+)
    (–)
    Resistance
    Joint connector (CAN2)
    Connector
    Terminal
    A-105
    5
    Body earth
    1 kΩ or more
    16
    <RHD>
    (+)
    (–)
    Resistance
    Joint connector (CAN2)
    Connector
    Terminal
    A-105
    1
    Body earth
    1 kΩ or more
    12
  5. Connect joint connector (CAN2) connector.
Are the check result normal?
YES <Resistance value is 1 kΩ or more in both terminals>
NO <Resistance value is less than 1 kΩ in either terminals>
10.Diagnose the ENG-LOCAL CAN [joint connector (CAN2) connector disconnected]
CAUTION:
Strictly observe the specified wiring harness repair procedure (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  1. Disconnect joint connector (CAN2) connector and read all diagnosis with M.U.T.-III SE.
  2. Confirm that all diagnosis reading result of the DCU is "NC".
Is all diagnosis reading result of the DCU "NC"?
YES
Repair the wiring harness between joint connector (CAN2) connector and joint connector connector.
NO
Check the joint connector, and repair if necessary. If the joint connector is in good condition, GO TO 11.
11.Diagnose the ENG-LOCAL CAN
  1. Read all diagnosis with M.U.T.-III SE.
  2. Confirm that all diagnosis reading result of the DCU is normal (other than "NC").
Is the check result normal?
YES
Intermittent malfunction (Refer to General Information – General – Basic Inspection – Service Information for Electrical Incident – INTERMITTENT INCIDENT).
NO
Check the joint connector connector, and repair if necessary.
12.Check the ENG-LOCAL CAN between joint connector (CAN2) and NOx sensor No. 1. Resistance measurement at joint connector (CAN2)
CAUTION:
  • A digital multimeter should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  • The test wiring harness should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  • When measuring the resistance, disconnect the negative battery terminal (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  1. Ensure that the negative battery terminal is disconnected.
  2. Disconnect joint connector (CAN2) connector.
  3. Check the harness connector side.
  4. Check resistance between joint connector (CAN2) connector and body earth.
    <LHD>
    (+)
    (–)
    Resistance
    Joint connector (CAN2)
    Connector
    Terminal
    A-105
    3
    Body earth
    1 kΩ or more
    15
    <RHD>
    (+)
    (–)
    Resistance
    Joint connector (CAN2)
    Connector
    Terminal
    A-105
    2
    Body earth
    1 kΩ or more
    13
  5. Connect joint connector (CAN2) connector.
Are the check result normal?
YES <Resistance value is 1 kΩ or more in both terminals>
NO <Resistance value is less than 1 kΩ in either terminals>
13.Diagnose the ENG-LOCAL CAN (NOx sensor No. 1 connector disconnected)
CAUTION:
Strictly observe the specified wiring harness repair procedure (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  1. Disconnect NOx sensor No. 1 connector and read all diagnosis with M.U.T.-III SE.
  2. Confirm that all diagnosis reading result of the DCU is "NC".
Is all diagnosis reading result of the DCU "NC"?
YES
Repair the wiring harness between joint connector (CAN2) connector and NOx sensor No. 1 connector.
NO
Check the NOx sensor No. 1 connector, and repair if necessary. If the NOx sensor No. 1 connector is in good condition, GO TO 14.
14.Diagnose the ENG-LOCAL CAN
  1. Read all diagnosis with M.U.T.-III SE.
  2. Confirm that all diagnosis reading result of the DCU is normal (other than "NC").
Is the check result normal?
YES
Intermittent malfunction (Refer to General Information – General – Basic Inspection – Service Information for Electrical Incident – INTERMITTENT INCIDENT).
NO
Check the NOx sensor No. 1 connector, and repair if necessary. If the NOx sensor No. 1 connector is in good condition, replace the NOx sensor No. 1 (Refer to UREA SCR SYSTEM SENSORS REMOVAL AND INSTALLATION).
15.Check the ENG-LOCAL CAN between joint connector (CAN2) and the engine-ECU. Resistance measurement at joint connector (CAN2).
CAUTION:
  • A digital multimeter should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  • The test wiring harness should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  • When measuring the resistance, disconnect the negative battery terminal (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  • Strictly observe the specified wiring harness repair procedure (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  1. Ensure that the negative battery terminal is disconnected.
  2. Disconnect joint connector (CAN2) connector.
  3. Check the harness connector side.
  4. Check resistance between joint connector (CAN2) connector and body earth.
    (+)
    (–)
    Resistance
    Joint connector (CAN2)
    Connector
    Terminal
    A-105
    3
    Body earth
    1 kΩ or more
    14
  5. Connect joint connector (CAN2) connector.
Are the check result normal?
YES <Resistance value is 1 kΩ or more in both terminals>
Repair the joint connector (CAN2).
NO <Resistance value is less than 1 kΩ in either terminals>
Repair the wiring harness between joint connector (CAN2) connector and engine-ECU connector.
16.Diagnose the ENG-LOCAL CAN (DCU connector disconnected)
  • Disconnect DCU connector and read all diagnosis with M.U.T.-III SE.
  • Confirm that all diagnosis reading result of the DCU is "NC".
Is all diagnosis reading result of the DCU "NC"?
YES
NO
Check the DCU connector, and repair if necessary. If the DCU connector is in good condition, GO TO 17.
17.Diagnose the ENG-LOCAL CAN
  • Read all diagnosis with M.U.T.-III SE.
  • Confirm that all diagnosis reading result of the DCU is normal (other than "NC").
Is the check result normal?
YES
Intermittent malfunction (Refer to General Information – General – Basic Inspection – Service Information for Electrical Incident – INTERMITTENT INCIDENT).
NO
Disconnect the DCU connector, then reconnect it securely.
18.Diagnose the ENG-LOCAL CAN
  • Read all diagnosis with M.U.T.-III SE.
  • Confirm that all diagnosis reading result of the DCU is normal (other than "NC").
Is the check result normal?
YES
Intermittent malfunction (Refer to General Information – General – Basic Inspection – Service Information for Electrical Incident – INTERMITTENT INCIDENT).
NO
Replace the engine-ECU (Refer to Engine – Diesel Fuel <4N1> – Engine-ECU – ENGINE-ECU REMOVAL AND INSTALLATION).
BookmarkedToo many bookmarks.
Please delete and bookmark again.