ENGINE - ENGINE AND EMISSION CONTROL - EMISSION CONTROL<4N1> - UREA SCR SYSTEM<EURO 6B OR EURO 6C> - UREA SCR TROUBLESHOOTING - SYMPTOM PROCEDURES - Diagnose shorts between CAN_H and L lines (ENG-LOCAL CAN)
DIAGNOSIS PROCEDURE: Diagnose shorts between CAN_H and L lines (ENG-LOCAL CAN)
N502634810000800ENG
1.Connector check: joint connector (CAN2)
CAUTION:
The strand end of the twist wire should be within 10 cm from the connector (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
When checking the joint connector (CAN2), ensure that its wiring harness side and its short pins are not damaged.
Is the check result normal?
YES
NO
Repair a defective connector or replace the joint connector (CAN2).
2.Resistance measurement at joint connector (CAN2)
CAUTION:
  • A digital multimeter should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  • The test wiring harness should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  • When measuring the resistance, disconnect the negative battery terminal (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  1. Turn the ignition switch to the "LOCK" (OFF) position.
  2. Ensure that the negative battery terminal is disconnected.
  3. Disconnect joint connector (CAN2) connector.
  4. Check the harness connector side.
  5. Check resistance between joint connector (CAN2) connector terminals.
    Joint connector (CAN2)
    Joint connector (CAN2)
    Resistance
    Connector
    Terminal
    Connector
    Terminal
    A-105
    13
    A-105
    14
    120 ± 20 Ω
Is the check result normal?
YES <Within 120 ± 20 Ω>
NO <Not within 120 ± 20 Ω>
3.Resistance measurement at engine-ECU connector
CAUTION:
  • A digital multimeter should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  • Strictly observe the specified wiring harness repair procedure (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  1. Remove the engine-ECU (Refer to Engine – Diesel Fuel <4N1> – Engine-ECU – ENGINE-ECU REMOVAL AND INSTALLATION).
  2. Check the equipment side.
  3. Check resistance between engine-ECU connector terminals.
    Engine-ECU
    Engine-ECU
    Resistance
    Connector
    Terminal
    Connector
    Terminal
    A-10
    221
    A-10
    222
    120 ± 20 Ω
Is the check result normal?
YES <Within 120 ± 20 Ω>
Repair the wiring harness between joint connector (CAN2) and engine-ECU connector.
NO <Not within 120 ± 20 Ω>
Check the engine-ECU connector, and repair if necessary. If the engine-ECU connector is in good condition, replace the engine-ECU (Refer to Engine – Diesel Fuel <4N1> – Engine-ECU – ENGINE-ECU REMOVAL AND INSTALLATION).
4.Resistance measurement at joint connector (CAN2)
CAUTION:
  • A digital multimeter should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  • The test wiring harness should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  • When measuring the resistance, disconnect the negative battery terminal (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  1. Turn the ignition switch to the "LOCK" (OFF) position.
  2. Ensure that the negative battery terminal is disconnected.
  3. Disconnect joint connector (CAN2) connector.
  4. Check the harness connector side.
  5. Check resistance between joint connector (CAN2) connector terminals.
    <LHD>
    Joint connector (CAN2)
    Joint connector (CAN2)
    Resistance
    Connector
    Terminal
    Connector
    Terminal
    A-105
    4
    A-105
    15
    1 kΩ or more
    <RHD>
    Joint connector (CAN2)
    Joint connector (CAN2)
    Resistance
    Connector
    Terminal
    Connector
    Terminal
    A-105
    2
    A-105
    13
    1 kΩ or more
Is the check result normal?
YES <1 kΩ or more>
NO <Less than 1 kΩ>
5.Resistance measurement at NOx sensor No.1 connector
CAUTION:
  • A digital multimeter should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  • Strictly observe the specified wiring harness repair procedure (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  1. Remove the NOx sensor No. 1 (Refer to UREA SCR SYSTEM SENSORS REMOVAL AND INSTALLATION).
  2. Check the equipment side.
  3. Check resistance between NOx sensor No. 1 connector terminals.
    NOx sensor No. 1
    NOx sensor No. 1
    Resistance
    Connector
    Terminal
    Connector
    Terminal
    A-128
    4
    A-128
    3
    1 kΩ or more
Is the check result normal?
YES <1 kΩ or more>
Repair the wiring harness between joint connector (CAN2) and NOx sensor No. 1 connector.
NO <Less than 1 kΩ>
Check the NOx sensor No. 1 connector, and repair if necessary. If the NOx sensor No. 1 connector is in good condition, replace the NOx sensor No. 1 (Refer to UREA SCR SYSTEM SENSORS REMOVAL AND INSTALLATION).
6.Resistance measurement at joint connector (CAN2)
CAUTION:
  • A digital multimeter should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  • The test wiring harness should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  • When measuring the resistance, disconnect the negative battery terminal (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  1. Turn the ignition switch to the "LOCK" (OFF) position.
  2. Ensure that the negative battery terminal is disconnected.
  3. Disconnect joint connector (CAN2) connector.
  4. Check the harness connector side.
  5. Check resistance between joint connector (CAN2) connector terminals.
    <LHD>
    Joint connector (CAN2)
    Joint connector (CAN2)
    Resistance
    Connector
    Terminal
    Connector
    Terminal
    A-105
    5
    A-105
    16
    1 kΩ or more
    <RHD>
    Joint connector (CAN2)
    Joint connector (CAN2)
    Resistance
    Connector
    Terminal
    Connector
    Terminal
    A-105
    1
    A-105
    12
    1 kΩ or more
Is the check result normal?
YES <1 kΩ or more>
NO <Less than 1 kΩ>
7.Connector check: joint connector
CAUTION:
The strand end of the twist wire should be within 10 cm from the connector (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
When checking the joint connector, ensure that its wiring harness side and its short pins are not damaged.
Is the check result normal?
YES
Repair the wiring harness between joint connector (CAN2) and joint connectorr.
NO
Repair a defective connector or replace the joint connector.
8.Resistance measurement at joint connector
CAUTION:
  • A digital multimeter should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  • The test wiring harness should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  • When measuring the resistance, disconnect the negative battery terminal (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  1. Turn the ignition switch to the "LOCK" (OFF) position.
  2. Ensure that the negative battery terminal is disconnected.
  3. Disconnect joint connector connector.
  4. Check the harness connector side.
  5. Check resistance between joint connector connector terminals.
    Joint connector (24)
    Joint connector (24)
    Resistance
    Connector
    Terminal
    Connector
    Terminal
    G-46
    3
    G-46
    2
    1 kΩ or more
Is the check result normal?
YES <1 kΩ or more>
NO <Less than 1 kΩ>
9.Resistance measurement at NOx sensor No. 3 connector
CAUTION:
  • A digital multimeter should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  • Strictly observe the specified wiring harness repair procedure (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  1. Remove the NOx sensor No. 3 (Refer to UREA SCR SYSTEM SENSORS REMOVAL AND INSTALLATION).
  2. Check the equipment side.
  3. Check resistance between NOx sensor No. 3 connector terminals.
    NOx sensor No. 3
    NOx sensor No. 3
    Resistance
    Connector
    Terminal
    Connector
    Terminal
    G-47
    4
    G-47
    3
    1 kΩ or more
Is the check result normal?
YES <1 kΩ or more>
Repair the wiring harness between joint connector and NOx sensor No. 3 connector.
NO <Less than 1 kΩ>
Check the NOx sensor No. 3 connector, and repair if necessary. If the NOx sensor No. 3 connector is in good condition, replace the NOx sensor No. 3 (Refer to UREA SCR SYSTEM SENSORS REMOVAL AND INSTALLATION).
10.Resistance measurement at joint connector
CAUTION:
  • A digital multimeter should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  • The test wiring harness should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  • When measuring the resistance, disconnect the negative battery terminal (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  1. Turn the ignition switch to the "LOCK" (OFF) position.
  2. Ensure that the negative battery terminal is disconnected.
  3. Disconnect joint connector connector.
  4. Check the harness connector side.
  5. Check resistance between joint connector connector terminals.
    Joint connector (24)
    Joint connector (24)
    Resistance
    Connector
    Terminal
    Connector
    Terminal
    G-46
    4
    G-46
    1
    1 kΩ or more
Is the check result normal?
YES <1 kΩ or more>
NO <Less than 1 kΩ>
11.Resistance measurement at PM sensor connector
CAUTION:
  • A digital multimeter should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  • Strictly observe the specified wiring harness repair procedure (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  1. Remove the PM sensor (Refer to UREA SCR SYSTEM SENSORS REMOVAL AND INSTALLATION).
  2. Check the equipment side.
  3. Check resistance between PM sensor connector terminals.
    PM sensor
    PM sensor
    Resistance
    Connector
    Terminal
    Connector
    Terminal
    G-45
    3
    G-45
    2
    1 kΩ or more
Is the check result normal?
YES <1 kΩ or more>
Repair the wiring harness between joint connector and PM sensor connector.
NO <Less than 1 kΩ>
Check the PM sensor connector, and repair if necessary. If the PM sensor connector is in good condition, replace the PM sensor (Refer to UREA SCR SYSTEM SENSORS REMOVAL AND INSTALLATION).
12.Resistance measurement at joint connector
CAUTION:
  • A digital multimeter should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  • The test wiring harness should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  • When measuring the resistance, disconnect the negative battery terminal (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  1. Turn the ignition switch to the "LOCK" (OFF) position.
  2. Ensure that the negative battery terminal is disconnected.
  3. Disconnect joint connector connector.
  4. Check the harness connector side.
  5. Check resistance between joint connector connector terminals.
    Joint connector (24)
    Joint connector (24)
    Resistance
    Connector
    Terminal
    Connector
    Terminal
    G-46
    8
    G-46
    5
    120 ± 20 Ω
Is the check result normal?
YES <Within 120 ± 20 Ω>
Intermittent malfunction (Refer to General Information – General – Basic Inspection – Service Information for Electrical Incident – INTERMITTENT INCIDENT).
NO <Not within 120 ± 20 Ω>
13.Resistance measurement at DCU connector
CAUTION:
  • A digital multimeter should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  • Strictly observe the specified wiring harness repair procedure (For details refer to Electrical & Power Control – Controller Area Network (CAN) – SERVICE PRECAUTIONS).
  1. Remove the DCU (Refer to DCU REMOVAL AND INSTALLATION).
  2. Check the equipment side.
  3. Check resistance between DCU connector terminals.
    DCU
    DCU
    Resistance
    Connector
    Terminal
    Connector
    Terminal
    A-129
    87
    A-129
    65
    120 ± 20 Ω
Is the check result normal?
YES <Within 120 ± 20 Ω>
Repair the wiring harness between joint connector and DCU connector.
NO <Not within 120 ± 20 Ω>
Check the DCU connector, and repair if necessary. If the DCU connector is in good condition, disconnect the DCU connector, then reconnect it securely.