Item No. | M.U.T.-III SE display | Test contents | Inspection conditions | Value to be determined as normal |
1 | Urea hose heater | Turn the urea feed tube heater ON |
| Energise the urea feed tube heater for approximately 10 seconds. (Data list item No. 58: Urea hose heater operate state is turned to "ON") |
2 | Urea tank heater | Turn the urea tank heater ON |
| Energise the urea tank heater for approximately 10 seconds. (Data list item No. 51: Urea tank heater status is turned to "ON") |
3 | Urea injector 1 Dosing | Urea injector is driven. |
| Operating noise is heard. (Out put data list item No. 52: Urea injector 1 drive duty value) |
Item No. | M.U.T.-III SE display | Test contents | Inspection conditions | Normal condition |
1 | Urea level/quality sensor sonar test | Sonar test is forcibly carried out in the sonar diagnosis of urea level sensor or in the sonar diagnosis of urea quality sensor. | Ignition switch: "ON" position | It is normal if the diagnosis code (P203A-1F or P206A-1F) is not detected after the sonar test. |
Item No. | M.U.T.-III SE display | Test contents | Inspection conditions | Normal condition |
1 | Urea injector 1 Dosing test | Check that the urea water can be injected normally. |
| Operating noise is heard. (Out put data list item No. 52: Urea injector 1 drive duty value) |
2 | Urea line emptying test | Drain urea water from the urea feed tube. | Ignition switch: "ON" position (but do not start the engine) | The back flow pump is activated and the urea water in the urea feed tube is returned to the urea tank. |
3 | Urea pump first filling test | Draw back and empty the urea water in the urea feed tube (Urea feed tube). The purpose is to reduce pressure and prevent urea water leakage when disconnecting the urea line (injector and hose). If the pressure remains high, the parts cannot be removed. | Ignition switch: "ON" position (but do not start the engine) | The back flow pump is activated and the urea water in the urea feed tube is returned to the urea tank. |
4 | Urea pumping and Dosing test | The urea pressure feed pump (Supply pump) is driven to pump urea water from the urea tank to the urea feed tube to boost pressure. | Ignition switch: "ON" position (but do not start the engine) | The supply pump is activated and the urea water in the urea tank is sent to the urea feed tube. |
5 | Urea SCR system test | The following items are performed in the order below.
The air bleeding inside the pump and the pump function check can be performed at the same time. |
| It is normal if the entire series of tests is completed. |
6 | Urea leak test | Raise and hold the urea water pressure and check for pressure drop. The purpose is to check for urea water leakage from the urea injector and urea feed tube. | Ignition switch: "ON" position (but do not start the engine) | No leakage of urea water from the urea injector and urea feed tube |
Item No. | M.U.T.-III SE display | Content |
1 | SCR Catalyst 1 initialization | After replacement of the main catalytic converter (SCR-DPF), initialise the values related to the SCR-DPF stored in the DCU . |
2 | NOx sensor 1 initialization | After replacement of NOx sensor No. 1, initialise the values related to NOx sensor No. 1 stored in the DCU. |
3 | NOx sensor 3 initialization | After replacement of NOx sensor No. 3, initialise the values related to NOx sensor No. 3 stored in the DCU. |
4 | SCR exhaust temperature sensor initialization | After replacement of the exhaust gas temperature sensor No. X, initialise the values related to exhaust gas temperature sensor No. X stored in the DCU. |
5 | DCU initialization (without value transfer) | This item is displayed, but is not used. |
6 | DCU initialization (with value transfer) | |
7 | DOC initialization | After replacement of the main catalytic converter (DOC), initialise the values related to DOC stored in the DCU. |
8 | DPF initialization | After replacement of the main catalytic converter (DPF), initialise the values related to DPF stored in the DCU. |
9 | Urea injector 1 initialization | After replacement of the urea injector assembly, initialise the values related to urea injector stored in the DCU. |
10 | SCR Catalyst 2 initialization | After replacement of the catalytic converter (SCR), initialise the values related to SCR stored in the DCU. |
11 | Urea tank level update |
|
Item No. | M.U.T.-III SE display | Content |
1 | Urea injector 1 total dosed quantity reset | After replacement of the urea injector assembly, set the value of the total urea injection volume of the urea injector stored by the DCU to 0. (It is not necessary when the DCU is replaced since the total urea injection volume stored in the new DCU is set to 0 by default.) |
2 | Urea consumption error diagnosis value reset | After detecting an abnormal urea consumption diagnosis (diagnosis code No. P20F4-00 or P20F5-00) and carrying out the troubleshooting, reset the value used as the diagnosis threshold for the abnormal urea consumption diagnosis to its initial value. |