ENGINE - ENGINE AND EMISSION CONTROL - EMISSION CONTROL<4N1> - UREA SCR SYSTEM<EURO 6B OR EURO 6C> - ON-VEHICLE SERVICE
INITIALISATION PROCEDURE FOR UREA CONSUMPTION ERROR DIAGNOSIS VALUE
N502634920000I00ENG
CAUTION:
To prevent damage to the M.U.T.-III SE, always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting the M.U.T.-III SE.
NOTE:
In a normal SCR system, discharge amount of the AdBlue® from the urea pump and the injection amount of the urea injector will be equal. When the discharge amount and the injection amount are equal, the coefficient value used for diagnosis is 1.0, but when the discharge amount and the injection amount diverge due to AdBlue® leakage or urea injector clogging, etc., the value deviates from 1.0. If the deviation of the value exceeds the threshold, diagnosis code P20F4-00 or P20F5-00 is detected as urea consumption error diagnosis.
Make sure the diagnosis codes P20F5-00 or P20F4-00 are not set using M.U.T.-III SE. If set, carry out the troubleshooting for the set codes and solve the problems. (Refer to DIAGNOSIS CODE CHART)
YES>>
Go to step 2.
NO>>
Terminal the test.
Connect the M.U.T.-III SE to the diagnosis connector.
Turn the ignition switch to the "ON" position.
Select "UDCU" from System Select Screen of the M.U.T.-III SE.
From UDCU Screen, select "Special Function".
From Special Function Screen, select "Reset".
Carry out the "Item No. 2: Urea consumption error diagnosis value reset" from Reset Screen.
After turning the ignition switch to the "LOCK" (OFF) position, remove the M.U.T.-III SE.
BookmarkedToo many bookmarks.
Please delete and bookmark again.