ENGINE - ENGINE MECHANICAL<4G6> - ON-VEHICLE SERVICE
MANIFOLD VACUUM CHECK
N502640230000200ENG
Before inspection, set the vehicle to the pre-inspection condition.
Turn the ignition switch to the "LOCK" (OFF) position and then connect the M.U.T.-III SE to the diagnosis connector (Refer to General Information – General – Basic Inspection – M.U.T.-III SE Checking System – HOW TO USE DIAGNOSIS ITEMS).
Disconnect the ventilation hose from the positive crankcase ventilation (PCV) valve, and connect a vacuum gauge to the ventilation hose.
Plug the PCV valve.
Start the engine and check that idle speed is within the standard value.
Standard value: 720 ± 100 r/min
Check the intake manifold vacuum.
Limit: Minimum 60 kPa
Turn the ignition switch to the "LOCK" (OFF) position.
Disconnect the vacuum gauge and then connect the ventilation hose.
Disconnect the M.U.T.-III SE.
BookmarkedToo many bookmarks.
Please delete and bookmark again.