Disconnect the injector connector of all cylinders.
NOTE:
Doing this will prevent carrying out fuel injection.
CAUTION:
Keep away from the glow plug hole when cranking.
If compression is measured with water, oil, fuel, etc., that has come from cracks inside the cylinder, these materials will become heated and will gush out from glow plug hole, which is dangerous.
Cover the glow plug hole with a shop towel etc., and after the engine has been cranked, check that no foreign material is adhering to the shop towel.
CAUTION:
Install special service tool compression pressure test adapter (MB992285), tighten to the torque that is less than the tightening torque (18 ± 2 N· m) of the glow plug.
Install the special service tool compression pressure test adapter (MB992285) to the glow plug installation hole and install the compression gauge.
Crank the engine and measure the compression pressure.
Standard value (at engine speed of 200 r/min): 2,400 kPa
Limit (at engine speed of 200 r/min): Minimum 2,100 kPa
Measure the compression pressure for all the cylinders, and check that the pressure differences of the cylinders are below the limit.
Limit (at engine speed of 200 r/min): Maximum 300 kPa
If there is a cylinder with compression or a compression difference that is outside the limit, pour a small amount of engine oil through the glow plug hole, and repeat the operations in steps from 6 to 8.
If the compression increases after oil is added, the cause of the malfunction is a worn or damaged piston ring and/or cylinder inner surface.
If the compression does not rise after oil is added, the cause is a burnt or defective valve seat, or pressure is leaking from the gasket.
Turn the ignition switch to "LOCK" (OFF) position.
To prevent damage to the M.U.T.-III SE, always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting the M.U.T.-III SE.
Turn the ignition switch to the "LOCK" (OFF) position and then connect the M.U.T.-III SE to the diagnosis connector (Refer to General Information – General – Basic Inspection – M.U.T.-III SE Checking System – HOW TO USE DIAGNOSIS ITEMS).
Use the M.U.T.-III SE to erase the diagnosis codes.
NOTE:
This will erase the diagnosis code resulting from the injector connector being disconnected.