Diagnosis Code No. | M.U.T.-III SE Screen Items [Diagnosis item] | Diagnosis Code Detection Condition | |
P1603-14 | Battery backup circuit malfunction [Battery backup circuit malfunction] | Diagnosis condition |
|
Signal (terminal) | Battery backup voltage | ||
Threshold | Battery backup voltage is less than 6 V. | ||
Diagnosis delay time | 2 seconds | ||