Diagnosis Code No. | M.U.T.-III SE Screen Items [Diagnosis item] | Diagnosis Code Detection Condition | |
P2229-00 | Barometric pressure sensor circuit high input [Barometric pressure sensor circuit high input] | Diagnosis condition |
|
Signal (terminal) | Barometric pressure sensor | ||
Threshold | Barometric pressure sensor output signal is more than 113 kPa (approximately 1,200 m below sea level). | ||
Diagnosis delay time | 10 seconds | ||