1.CHECK TRANSFER ACTUATOR CIRCUIT (SHORT TO EARTH)
Disconnect the transfer-ECU connector and the transfer actuator connector.
Check the continuity between the transfer-ECU connector terminals and body earth at the harness side.
(+) | (-) | Continuity |
Transfer-ECU |
Connector | Terminal |
A-04 | 55 | Body earth | No continuity |
54 |
Is the inspection result normal?
YES
NO
Repair or replace the connector(s) or wiring harness.
2.CHECK TRANSFER ACTUATOR CIRCUIT (OPEN)
Disconnect the transfer-ECU connector and the transfer actuator connector.
Check the continuity between the transfer-ECU connector terminals and the transfer actuator connector terminals at the harness side.
Transfer-ECU | Transfer actuator | Continuity |
Connector | Terminal | Connector | Terminal |
A-04 | 55 | G-04 | 5 | Existed (2 Ω or less) |
54 | 6 |
Is the inspection result normal?
YES
NO
Repair or replace the connector(s) or wiring harness.
3.CHECK TRANSFER ACTUATOR
Disconnect the transfer actuator connector.
Measure the resistance between the transfer actuator connector terminals at the equipment side.
Transfer actuator | Resistance |
Connector | Terminal |
G-04 | 5 – 6 | Less than 100 Ω |
Is the inspection result normal?
YES
NO
4.PERFORM DTC CONFIRMATION PROCEDURE
Is the DTC set?
YES
NO