A/T-ECU | Condition | Resistance | |
Connector | Terminal | ||
G-38 | 29 – 30 | A/T fluid temperature: 10°C | Approximately 6.5 kΩ |
A/T fluid temperature: 25°C | Approximately 3.5 kΩ (reference value) | ||
A/T fluid temperature: 110°C | Approximately 0.25 kΩ | ||
A/T-ECU | A/T control solenoid valve assembly | Continuity | ||
Connector | Terminal | Connector | Terminal | |
G-38 | 30 | G-42 | 8 | Existed (2 Ω or less) |
29 | 7 | |||