HEATER, AIR CONDITIONER AND VENTILATION - HEATER, AIR CONDITIONER AND VENTILATION - TROUBLESHOOTING<AUTO A/C>
CHECK AT ECU TERMINAL
N509000120000S00ENG
TERMINAL LAYOUT
PHYSICAL VALUES
C-06
Terminal No.
Description
Condition
Value
(+)
(−)
Signal name
Input/Output
1
3
Accessory power supply
Input
Ignition switch "LOCK" (OFF) position (auto ACC status) or ON
10.5 – 16 V
Ignition switch "LOCK" (OFF) position (not auto ACC status)
0 – 0.1 V
3
Earth
Earth
—
Ignition switch ON
0 – 0.1 V
8
32
Ion generator power supply
Output
Blower motor ON
0 – 12V
11
—
CAN-H
Input/Output
—
—
13
23
In-vehicle sensor signal
Input
Ignition switch ON
Sensor probe temperature: 25°C (2.186 kΩ): Approximately 0.882 V
14
23
Sunload sensor signal
Input
Ignition switch ON
16
—
LIN (heated seat)
Input/Output
—
—
23
Earth
Sensor earth (in-vehicle, sunload)
—
Ignition switch ON
0 – 0.1 V
31
—
CAN-L
Input/Output
—
—
32
—
Ion generator earth
—
—
0 – 0.1 V
33
—
LIN (A/C control)
Input/Output
—
—
35
32
Ion generator control
Output
Blower motor ON
0 – 5.0 V
H-04
Terminal No.
Description
Condition
Value
(+)
(−)
Signal name
Input/Output
20
C-06: 3
Door motor power supply
Output
—
—
27
C-06: 3
Blower motor control
Output
Ignition switch ON
Blower motor: OFF
10.5 – 16 V
Blower motor: 1st speed (manual)
Blower motor: 7th speed (manual)
34
Earth
Door motor earth
—
—
—
35
Earth
Sensor earth (intake)
—
Ignition switch ON
0 – 0.1 V
38
35
FIN thermo sensor signal
Input
Ignition switch ON