HEATER, AIR CONDITIONER AND VENTILATION - HEATER, AIR CONDITIONER AND VENTILATION - TROUBLESHOOTING<MANUAL A/C> - DIAGNOSIS CODE PROCEDURES - B24A4-11 Evap temperature sensor (short circuit)
DTC Description: B24A4-11
N509001170000300ENG
DTC DETECTION LOGIC
DTC No.
M.U.T.-III SE screen terms
(Trouble diagnosis content)
DTC detection condition
B24A4-11
Evap temperature sensor (short circuit)
(Fin thermo sensor)
Diagnosis condition
Ignition switch ON
Signal (Terminal)
Fin thermo sensor signal
Threshold
The fin thermo sensor recognition temperature is too high [more than 100°C]
Diagnosis delay time
2 seconds or more
POSSIBLE CAUSE
  • Fin thermo sensor
  • A/C-ECU
  • Harness or connectors (the sensor circuit is shorted to earth)
FAIL-SAFE
—
DTC CONFIRMATION PROCEDURE
1.PERFORM DTC CONFIRMATION PROCEDURE
With M.U.T.-III SE
  1. Ignition switch ON.
  2. Select “Self-diagnosis” of “HVAC” using M.U.T.-III SE.
  3. Check DTC.
Is DTC detected?
YES
NO-1
To check malfunction symptom before repair: Refer to General information - General - Basic inspection - Service information for electrical incident - INTERMITTENT INCIDENT.
NO-2
Confirmation after repair: INSPECTION END
BookmarkedToo many bookmarks.