HEATER, AIR CONDITIONER AND VENTILATION - HEATER, AIR CONDITIONER AND VENTILATION - TROUBLESHOOTING<AUTO A/C> - CIRCUIT DIAGNOSIS PROCEDURE - POWER SUPPLY AND EARTH CIRCUIT - ION GENERATOR
Diagnosis Procedure: Power supply and earth circuit
N509002240001100ENG
1.CHECK ION GENERATOR POWER SUPPLY VOLTAGE
  1. Disconnect the ion generator connector.
  2. Turn the ignition switch to the "ON" position.
  3. Check voltage between the ion generator harness connector and body earth.
    (+)
    (–)
    Voltage
    Ion generator
    Connector
    Terminal
    C-43
    1
    Body earth
    Battery voltage
Is the inspection result normal?
YES
NO
2.CHECK ION GENERATOR POWER SUPPLY CIRCUIT (OPEN AND SHORT CIRCUIT)
  1. Turn the ignition switch to the "LOCK" (OFF) position.
  2. Disconnect the ion generator connector and A/C-ECU connector.
  3. Check continuity between the ion generator harness connector and A/C-ECU harness connector.
    Ion generator harness connector
    A/C-ECU harness connector
    Continuity
    Connector
    Terminal
    Connector
    Terminal
    C-43
    1
    C-06
    8
    Existed
  4. Check continuity between the ion generator harness connector and body earth.
    Ion generator
    –
    Continuity
    Connector
    Terminal
    C-43
    1
    Body earth
    Not existed
Is the inspection result normal?
YES
NO
Repair harness or connector.
3.CHECK ION GENERATOR EARTH CIRCUIT (OPEN CIRCUIT)
  1. Turn the ignition switch to the "LOCK" (OFF) position.
  2. Connect the A/C-ECU connector.
  3. Check continuity between ion generator harness connector and body earth.
    Ion generator
    –
    Continuity
    Connector
    Terminal
    C-43
    4
    Body earth
    Existed
Is the inspection result normal?
YES
Inspection end.
NO
Repair or replace root cause.
BookmarkedToo many bookmarks.