ELECTRICAL & POWER CONTROL - CONTROLLER AREA NETWORK (CAN) - TROUBLESHOOTING<CAN> - CAN BUS DIAGNOSIS - IT CAN COMMUNICATION CIRCUIT - BRANCH LINE - IT CAN 2 COMMUNICATION CIRCUIT
COMBINATION METER BRANCH LINE CIRCUIT
N514181120000500ENG
1.CHECK CONNECTOR
  1. Turn the ignition switch to the "LOCK" (OFF) position.
  2. Disconnect the battery cable from the negative terminal.
  3. Check the following terminals and connectors for damage, bend and loose connection (unit side and harness side).
    • Combination meter
Is the inspection result normal?
YES
NO
Repair the terminal and connector.
2.CHECK HARNESS FOR OPEN CIRCUIT
  1. Disconnect the connector of the combination meter.
  2. Check the resistance between the combination meter harness connector terminals.
    Combination meter harness connector
    Resistance (Ω)
    Connector No.
    Terminal No.
    C-11
    21
    22
    Approx. 54 – 66
Is the measurement value within the specification?
YES
NO
Repair or replace the malfunctioning part.
3.CHECK POWER SUPPLY AND EARTH CIRCUIT
Check the power supply and the earth circuit of the combination meter. Refer to Electrical & Power Control – Chassis Electrical – Combination Meter – Troubleshooting – Circuit Diagnosis Procedures – Power Supply and Earth Circuit – Diagnosis Procedure: Power supply and earth circuit.
Is the inspection result normal?
YES (Present error)
Replace the combination meter. Refer to Electrical & Power Control – Chassis Electrical – Combination Meter – Combination Meter – COMBINATION METER REMOVAL AND INSTALLATION.
YES (Past error)
Error was detected in the combination meter branch line.
NO
Repair the power supply and the earth circuit.
BookmarkedToo many bookmarks.