1.CHECK BACK-UP LAMP BULB
Turn the ignition switch OFF.
Check the back-up lamp bulb.
Is the inspection result normal?
YES
NO
2.CHECK BACK-UP LAMP RELAY FUSE
Check that the following fuse is not blown (open).
Unit | Location | Fuse No. | Capacity |
Back-up lamp relay | Relay control unit | 71 | 10 A |
Is the fuse blown (open)?
YES
Replace the blown (open) fuse after repairing the affected circuit if a fuse is blown (open).
NO
3.CHECK BACK-UP LAMP RELAY POWER SUPPLY
Turn the ignition switch ON.
Check voltage between relay control unit harness connector and body earth.
(+) | (-) | Voltage |
Relay control unit |
Connector | Terminal |
A-19 | 1 | Body earth | 6 – 16 V |
Is the inspection result normal?
YES
NO
4.CHECK BACK-UP LAMP RELAY POWER SUPPLY CIRCUIT
Turn the ignition switch OFF.
Remove back-up lamp relay.
Disconnect relay control unit connector.
Check continuity between relay control unit harness connector and back-up lamp relay harness connector.
Relay control unit | Back-up lamp relay | Continuity |
Connector | Terminal | Connector | Terminal |
A-19 | 1 | A-33X | 4 | Existed |
3 |
Is the inspection result normal?
YES
NO
Repair or replace harness.
5.CHECK BACK-UP LAMP RELAY
Is the inspection result normal?
YES
NO
Replace back-up lamp relay.
6.CHECK BACK-UP LAMP RELAY CONTROL SIGNAL
Install back-up lamp relay.
Connect relay control unit connector.
Start the engine.
With operating the shift selector, check voltage between ETACS-ECU harness connector and body earth.
(+) | (-) | Condition | Voltage |
ETACS-ECU |
Connector | Terminal |
C-213 | 22 | Body earth | Shift selector position | R range | Approx. 0 V |
Except R range | 9 – 16 V |
Is the inspection result normal?
YES
NO-1
NO-2
7.CHECK BACK-UP LAMP RELAY CONTROL SIGNAL CIRCUIT
Turn the ignition switch OFF.
Remove back-up lamp relay.
Disconnect ETACS-ECU harness connector.
Check continuity between ETACS-ECU harness connector and back-up lamp relay harness connector.
ETACS-ECU | Back-up lamp relay | Continuity |
Connector | Terminal | Connector | Terminal |
C-213 | 22 | A-33X | 1 | Existed |
Is the inspection result normal?
YES
NO
Repair or replace harness.
8.CHECK BACK-UP LAMP POWER SUPPLY CIRCUIT 1
Turn the ignition switch OFF.
Remove back-up lamp relay.
Disconnect rear combination lamp connector.
Check continuity between back-up lamp relay harness connector and rear combination lamp (back door side) harness connector.
Back-up lamp relay | Rear combination lamp | Continuity |
Connector | Terminal | Connector | Terminal |
RH | A-33X | 5 | G-09 | 4 | Existed |
LH | G-19 |
Is the inspection result normal?
YES
NO
Repair or replace harness.
9.CHECK BACK-UP LAMP EARTH CIRCUIT
Check continuity between rear combination lamp harness connector and body earth.
Rear combination lamp | – | Continuity |
Connector | Terminal |
RH | G-09 | 5 | Body earth | Existed |
LH | G-19 |
Is the inspection result normal?
YES
Check the corresponding back-up lamp bulb socket. Repair or replace if necessary.
NO
Repair or replace harness.