ELECTRICAL & POWER CONTROL - CHASSIS ELECTRICAL - COMBINATION METER - TROUBLESHOOTING - DIAGNOSIS CODE PROCEDURES - U1321-55 Config unfinished
DTC Description: U1321-55
N514280940000200ENG
DTC DETECTION LOGIC
DTC No.
M.U.T.-III SE screen terms
(Trouble diagnosis content)
DTC detection condition
U1321–55
Config unfinished
(Configuration unfinished)
Diagnosis condition
When ignition switch is ON
Signal (terminal)
—
Threshold
Configuration is incomplete
Diagnosis delay time
—
POSSIBLE CAUSE
The configuration for combination meter is not done.
FAIL-SAFE
—
DTC CONFIRMATION PROCEDURE
1.PERFORM DTC CONFIRMATION PROCEDURE
With M.U.T.-III SE
  1. Turn ignition switch ON.
  2. Turn ignition switch OFF and wait at least 30 seconds.
  3. Select “Self-diagnostis” of “METER / M&A” using M.U.T.-III SE.
  4. Check DTC.
Is DTC "U1321-55" detected?
YES
NO-1
To check malfunction symptom before repair: Refer to General Information – General – Basic Inspection – Service Information for Electrical Incident – INTERMITTENT INCIDENT.
NO-2
Confirmation after repair: INSPECTION END