1.CHECK COMBINATION METER BUZZER CIRCUIT FOR OPEN
Turn ignition switch "LOCK" (OFF) position.
Disconnect combination meter harness connector and combination meter buzzer harness connector.
Check the continuity between combination meter harness connector and combination meter buzzer harness connector.
Combination meter | Combination meter buzzer | Continuity |
Connector | Terminal | Connector | Terminal |
C-11 | 17 | C-15 | 1 | Existed |
18 | 4 |
Is the inspection result normal?
YES
NO
Repair or replace malfunctioning parts.
2.CHECK COMBINATION METER BUZZER CIRCUIT FOR SHORT TO EARTH
Check the continuity between combination meter buzzer harness connector and earth.
Terminals | Continuity |
(+) | (−) |
Combination meter buzzer |
Connector | Terminal |
C-15 | 1 | Earth | Not existed |
4 |
Is the inspection result normal?
YES
NO
Repair or replace malfunctioning parts.