ELECTRICAL & POWER CONTROL - CHASSIS ELECTRICAL - ETACS - TROUBLESHOOTING - DIAGNOSIS CODE PROCEDURES - U2175-87 CAN comm err (Multi Around Monitor)
Diagnosis Procedure: U2175-87
N514311700000100ENG
1.CHECK CAN COMMUNICATION SYSTEM
Check CAN communication system. Refer to Electrical & Power Control – Controller Area Network (CAN) – Troubleshooting – CAN BUS DIAGNOSIS PROCEDURE.
INSPECTION END