ELECTRICAL & POWER CONTROL - CHASSIS ELECTRICAL - ETACS - TROUBLESHOOTING - SYMPTOM PROCEDURES - COMBINATION SWITCH SYSTEM SYMPTOMS
Column switch symptom table
N514311920000300ENG
  1. Using the M.U.T.-III SE, perform "Data List" of the ETACS-ECU (column switch).
  2. Check that the data list display switches in conjunction with the column switch operation.
  3. If there is a switch whose display does not change, specify the applicable column switch circuit (INPUT 1 - 6 and OUTPUT 1 - 5) using the column switch circuit confirmation table for the circuit used for that switch.
    NOTE:
    Since column switch circuit is share with multiple switches, if the switches used other than the defective switch are normal, the column switch circuit can be determined to be normal.
    Example: If the circuit used for the switch corresponds to INPUT 1 and OUTPUT 2 of the column switch circuit, but the other switches that use the INPUT 1 circuit are normal, it is determined that the INPUT 1 circuit is normal and inspect OUTPUT 2 circuit. If other switches that use OUTPUT 2 circuit are normal, the column switch circuit (INPUT 1 and OUTPUT 2) is determined to be normal, and it can be determined that the column switch is defective.
    Column switch circuit confirmation table
    Circuit used: ×
    Data list item
    Column switch circuit
    INPUT 1
    INPUT 2
    INPUT 3
    INPUT 4
    INPUT 5
    INPUT 6
    OUTPUT 1
    OUTPUT 2
    OUTPUT 3
    OUTPUT 4
    OUTPUT 5
    Check diode 1
    ×
    ×
    High beam switch
    ×
    ×
    Passing switch
    ×
    ×
    Rear fog switch
    ×
    ×
    Front fog switch
    ×
    ×
    INT volume 1
    ×
    ×
    Check diode 2
    ×
    ×
    Low beam switch
    ×
    ×
    AUTO light switch
    ×
    ×
    Taillight switch
    ×
    ×
    Front washer switch
    ×
    ×
    Check diode 3
    ×
    ×
    Turn signal LH
    ×
    ×
    Turn signal RH
    ×
    ×
    Front wiper LO
    ×
    ×
    Front wiper HI
    ×
    ×
    Front wiper INT
    ×
    ×
    Check diode 4
    ×
    ×
    Light OFF switch
    ×
    ×
    INT volume 2
    ×
    ×
    INT volume 3
    ×
    ×
    Check diode 5
    ×
    ×
    Front wiper OFF
    ×
    ×
    Front wiper MIST
    ×
    ×
  4. Identify the possible malfunctioning part from column switch circuit confirmation table and inspection or replace it.
    Possible malfunction part / Symptom
    Inspection / Replace
    Some data list displays do not switch
    There is a malfunction with either of the column switch INPUT circuit
    Inspect the column switch input circuit applicable to the malfunctioning part. Refer to Diagnosis Procedure: Column switch input circuit.
    There is a malfunction with either of the column switch OUTPUT circuit
    Inspect the column switch output circuit applicable to the malfunctioning part. Refer to Diagnosis Procedure: Column switch output circuit.
    It is not applicable to any of the column switch INPUT circuit and OUTPUT circuit
    Replace the column switch. Refer to COLUMN SWITCH REMOVAL AND INSTALLATION.
    If the data list display does not switch for a specific switch, the corresponding switch has a malfunction.
    All data list displays do not switch
    Replace ETACS-ECU. Refer to ETACS-ECU REMOVAL AND INSTALLATION.
    All data list displays switch
    Check intermittent incident. Refer to General Information – General – Basic Inspection – Service Information for Electrical Incident – INTERMITTENT INCIDENT.
BookmarkedToo many bookmarks.