ELECTRICAL & POWER CONTROL - CHASSIS ELECTRICAL - HAZARD WARNING LAMP SWITCH - TROUBLESHOOTING - CIRCUIT DIAGNOSIS PROCEDURE - HAZARD SWITCH CIRCUIT
Diagnosis Procedure: Hazard warning lamp switch circuit
N514380130000200ENG
1.CHECK HAZARD WARNING LAMP SWITCH SIGNAL
  1. Turn the ignition switch OFF.
  2. Disconnect hazard warning lamp switch connector.
  3. Check voltage between hazard warning lamp switch connector and body earth.
    +
    -
    Voltage
    Hazard warning lamp switch
    Connector
    Terminal
    C-07
    3
    Body earth
    9 – 16 V
Is the inspection result normal?
YES
NO
2.CHECK HAZARD WARNING LAMP SWITCH SIGNAL CIRCUIT (OPEN)
  1. Disconnect ETACS-ECU connector.
  2. Check continuity between hazard warning lamp switch harness connector and ETACS-ECU harness connector.
    Hazard warning lamp switch
    ETACS-ECU
    Continuity
    Connector
    Terminal
    Connector
    Terminal
    C-07
    3
    C-210
    8
    Existed
Is the inspection result normal?
YES
NO
Repair or replace harness.
3.CHECK HAZARD WARNING LAMP SWITCH SIGNAL CIRCUIT (SHORT)
Check continuity between hazard warning lamp switch harness connector and body earth.
Hazard warning lamp switch
—
Continuity
Connector
Terminal
C-07
3
Body earth
Not existed
Is the inspection result normal?
YES
Replace ETACS-ECU. Refer to ETACS-ECU REMOVAL AND INSTALLATION.
NO
Repair or replace harness.
4.CHECK HAZARD WARNING LAMP SWITCH EARTH CIRCUIT
Check continuity between hazard warning lamp switch harness connector and body earth.
Hazard warning lamp switch
—
Continuity
Connector
Terminal
C-07
2
Body earth
Existed
Is the inspection result normal?
YES
NO
Repair or replace harness.
5.CHECK HAZARD WARNING LAMP SWITCH
Check hazard warning lamp switch. Refer to Component Inspection: Hazard warning lamp switch circuit.
Is the inspection result normal?
YES
INSPECTION END
NO
Replace hazard warning lamp switch. Refer to HAZARD WARNING LAMP SWITCH REMOVAL AND INSTALLATION.
BookmarkedToo many bookmarks.