ENGINE - ENGINE AND EMISSION CONTROL<4N1> - EMISSION CONTROL -
UREA SCR SYSTEM <EURO 6B OR EURO 6C>
N102430060000B00ENG
To purify the exhaust gas, the Urea Selective Catalytic Reduction (SCR) system has been adopted.
The Urea SCR system is a system that purifies NOx by injecting AdBlue® into the exhaust pipe. It purifies NOx efficiently by increasing the SCR temperature.
NOTE:
AdBlue®: trademark of the Verband der Automobilindustrie e.V. (VDA).
COMPONENT PARTS LOCATION
<Urea SCR System>
1
NOx sensor No. 1
2
Main catalytic converter assembly
3
Urea injector assembly
4
Catalytic converter assembly
5
NOx sensor No. 3
6
PM sensor
7
Urea feed tube (Built in heater)
8
Urea filler
9
Urea tank assembly (Built in Urea pump module)
10
Urea filler cap
11
Dosing Control Unit (DCU)
<Urea Injector Cooling System>
1
Urea injector assembly
2
Electric water pump
3
Water control valve
4
Radiator
5
Water pipe
6
Water hose
7
Engine-ECU
8
Dosing Control Unit (DCU)
9
Water pump (mechanical type)
SYSTEM CONFIGURATION DIAGRAM
<Urea SCR System>
NOTE:
  • SCU*1: Sensor Control Unit
  • DOC*2: Diesel Oxidation Catalyst
  • SCR-DPF*3: Diesel Particulate Filter with Selective Catalytic Reduction
  • SCR*4: Selective Catalytic Reduction
  • ASC*5: Ammonia Slip Catalyst
<Urea Injector Cooling System>
OPERATION
<Urea SCR System>
The urea SCR system is controlled as follows according to the operation status.
  1. When the ignition switch is turned to the "ON" position and immediately after the engine is started.
    The urea SCR system is activated by turning the ignition switch to the "ON" position. In temperature conditions where AdBlue® is not likely to freeze (ambient air temperature and temperature in the urea tank above –7°C), the DCU activates the urea pump (supply pump) to start the pressure feeding of AdBlue®. When the urea pressure reaches a predetermined pressure, the DCU permits AdBlue® injection.
    The DCU estimates the emission amount of NOx from the operation status of the engine, and determines the AdBlue® injection quantity immediately after the engine is started according to the ammonia storage quantity of the SCR and NOx reduction efficiency.
  2. Immediately after the engine is started (when AdBlue® is frozen).
    When the urea tank assembly temperature is low, the DCU energises the urea tank heater and the urea line tube heater to perform thawing control of AdBlue®, because AdBlue® freezes when the temperature drops to –11°C or less. When the urea pressure reaches a predetermined pressure after thawing control is performed for a predetermined time and the urea pump (supply pump) is activated, the DCU permits AdBlue® injection. If the urea pressure does not reach the predetermined pressure, the thawing control is performed again.
    Even when AdBlue® injection is permitted, the DCU energises the urea tank heater and the urea line tube heater to prevent AdBlue® from freezing again if the urea tank assembly temperature or ambient temperature is low.
  3. During normal operation.
    When the exhaust pipe is heated by the exhaust gas sufficiently, the DCU activates the NOx sensor (The NOx sensor prevents the element from getting damaged by water drops to perform sensing while keeping the internal heater at high temperature).
  4. During normal operation (DPF regeneration is in progress).
    Due to higher exhaust gas temperatures during DPF regeneration, more AdBlue® may be injected than usual to cool the urea injector assembly.
  5. When the Auto Stop & Go (AS&G) system auto stop is activated.
    The DCU deactivates the urea injector assembly and the urea pump (supply pump) while maintaining the urea pressure before the automatic stop is activated.
  6. After the ignition switch is turned to the "LOCK" (OFF) position.
    The DCU activates the urea pump (back flow pump) to return the AdBlue® in the urea line tube to the urea tank assembly.
<Urea Injector Cooling System>
The urea injector cooling system prevents the urea injector assembly assembled to the main catalytic converter assembly from becoming hot and damaged after engine is stopped*. (The system only operates when the engine is stopped.)
NOTE:
*: Engine stopped means that the key is in the off state or the auto-stop is in operation.
The urea injector assembly is cooled by the engine coolant, which is circulated by the water pump (mechanical type) in the engine assembly during engine operation.
When the engine is stopped, the water pump (mechanical type) in the engine assembly is deactivated and the engine coolant flow is stopped.
If the area around the urea injector assembly is hot when the engine is stopped (because the engine coolant does not circulate when the engine is stopped), the urea injector assembly may become hot and damaged.
Therefore, when the engine is stopped, the outside air temperature and exhaust air temperature are checked and if the urea injector assembly is likely to be hot, the electric water pump is driven for a certain period of time to circulate the engine coolant to cool the urea injector assembly.
Depending on the operating conditions, the system is controlled as follows.
When the engine is running
  • The water pump (mechanical type) in the engine assembly is driving, the engine coolant is circulating and the electric water pump is stopped.
When the engine is stopped
  • The DCU checks the outside air temperature and exhaust air temperature.
  • The engine-ECU drives the electric water pump for a certain period of time if the urea injector assembly is likely to be hot when the engine is stopped.
  • Engine coolant is circulated to cool the urea injector assembly.
NOx REDUCTION PROCESS ON SCR CATALYST
AdBlue® injected from the urea injector assembly is mixed and dispersed by the mixer, and it adheres on the SCR catalyst. AdBlue® generates ammonia by hydrolysis, and the generated ammonia is adsorbed to the SCR catalyst. The ammonia adsorbed on the SCR catalyst purifies the nitrogen oxide as a reducing agent, and it generates nitrogen gas and water vapour.
DOSING CONTROL UNIT (DCU)
The DCU is installed under the driver's side instrument panel <LHD> or at the passenger’s side cowl side <RHD>. The DCU grasps the amount of NOx and the state of AdBlue® according to the signals from each sensor, and it performs the drive control of the urea pump, the heater control of the urea tank assembly and the urea line tube, and the injection control of the urea injector assembly, and displays the cruising range with warning in the combination meter.
<DCU Connector Input/output Pin Arrangement>
Terminal No.
Terminal code
Terminal name
Terminal No.
Terminal code
Terminal name
1
BAT1
Power supply
2
THS
Urea tank heater
3
BAT3
Power supply
4
GND
DCU earth
5
BAT2
Power supply
6
LHS
Urea feed tube heater
7, 8
–
–
9
INJ+
Urea injector (+)
10
PPS
Back flow pump (+)
11
MCPS
Supply pump (+)
12 to 15
–
–
16
TLS
Temperature/Level/Concentration sensor (TLC sensor)
17 to 22
–
–
23
C/R
Urea SCR relay
24 to 30
–
–
31
INJ–
Urea injector (–)
32
PPD
Back flow pump (–)
33
MCPD
Supply pump (–)
34 to 37
–
–
38
RPS
Pressure sensor
39, 40
–
–
41
TLSE
TLC sensor earth
42 to 64
–
–
65
CANL
CAN interface (low)
66
IGN
Power supply (Ignition switch: IG1)
67 to 84
–
–
85
RPSE
Pressure sensor earth
86
–
–
87
CANH
CAN interface (high)
88
–
–
89
TLSS
Power supply voltage applied to TLC sensor
90
–
–
91
RPSS
Power supply voltage applied to pressure sensor
92 to 94
–
–
NOx SENSOR
The NOx sensor No. 1 is installed to the main catalytic converter assembly (upstream area of the SCR-DPF) and the NOx sensor No. 3 is installed to the catalytic converter assembly (downstream area of the ASC). NOx sensor is consist of a detector (sensor probe) that detects NOx concentration and SCU that communicates with the DCU. The NOx sensor measures the NOx concentration in the exhaust gas and communicates it to the DCU by CAN. The DCU calculates an appropriate AdBlue® injection amount based on the NOx concentration received from the NOx sensor.
PM SENSOR
The PM sensor is installed to the catalytic converter assembly (downstream area of the ASC). PM sensor is consist of a detector (sensor probe) that detects PM amount and SCU that communicates with the DCU. The PM sensor measures the PM amount in the exhaust gas and communicates it to the DCU by CAN. The DCU performs failure diagnosis of the DPF based on the PM amount received from the PM sensor.
UREA INJECTOR ASSEMBLY
The urea injector assembly is installed to the main catalytic converter assembly (between the DOC and SCR-DPF). The urea injector assembly has an cooling system in its main body by engine coolant. AdBlue® is supplied from the urea pump to the urea injector assembly, and the urea injector assembly injects AdBlue® according to the injection control signal sent from the DCU.
UREA PUMP MODULE
The urea pump module is installed to the bottom of the urea tank assembly. The urea pump module incorporates a level sensor which measures the remaining amount of AdBlue® in the urea tank assembly, a temperature sensor which measures the temperature of AdBlue® and a heater which prevents AdBlue® from freezing. The urea pump has 2 pump systems: the supply pump which supplies AdBlue® to the urea injector assembly and the back flow pump which returns AdBlue® to the urea tank assembly.
ELECTRIC WATER PUMP
The electric water pump is installed to the bottom of the radiator.
WATER CONTROL VALVE
The water control valve is installed to the bottom of the radiator.