Item | Outline of function |
A/C controller assembly | Sends the blower speed setting signal to the A/C-ECU. |
A/C-ECU | When the blower speed setting is except OFF, an operation request signal is sent to the ion generator. |
Ion generator | Generates the ion when the ion generator operation request signal is sent from the A/C controller assembly (A/C-ECU). During the operation, it sends the ion generator operation signal to the A/C controller assembly (A/C-ECU). |
Ventilator joint duct | Ion generated from the ion generator is discharged through the duct. |