PURGE CONTROL SOLENOID VALVE CHECKN5024800T0000300ENG
Disconnect the vacuum hose from the purge control solenoid valve.
Disconnect the purge control solenoid valve connector.
Remove the purge control solenoid valve from the inlet manifold.
Connect a hand vacuum pump to nipple (A) of the solenoid valve (refer to the illustration at left).
Check airtightness by applying vacuum with voltage applied directly from the battery to the solenoid valve and without applying voltage.
| | Battery voltage | State of nipple B | Normal condition | Applied | Opened | Vacuum leaks | plugged | Vacuum maintained | Not applied | Opened | Vacuum maintained |
|
Measure the resistance between the terminals of the solenoid valve.
Standard value: 22 - 26 Ω (at 20°C)