Item No. | M.U.T.-III SE display | Drive contents | Inspection conditions | Normal condition |
1 | DPF regeneration | Force DPF regeneration |
| The forcible DPF regeneration is performed. |
Item No. | M.U.T.-III SE display | Drive contents | Inspection conditions | Normal condition |
1 | Fuel leakage check active test | Remain the following conditions for 20 seconds or more
|
| The following conditions remain for 20 seconds or more.
|
Item No. | M.U.T.-III SE display | Drive contents | Inspection conditions | Normal condition |
1 | Glow lamp | Turn the glow lamp on | IgniIgnition switch: "ON" position | The glow lamp turns on. |
2 | EGR cooler bypass solenoid | Turn the EGR cooler bypass control solenoid valve on |
| EGR cooler bypass control solenoid valve is driven. |
3 | Fuel suction control valve | Turn the suction control valve ON |
| Suction control valve is driven. |
4 | Fuel pump drive | Drive the fuel pump |
| Operating noise is heard. |
5 | Fuel injector cylinder #1 | Drive the No. 1 fuel injector |
| Operating noise is heard. |
Cut off the No. 1 fuel injector |
| Engine is changed (becomes unstable) | ||
6 | Fuel injector cylinder #2 | Drive the No. 2 fuel injector |
| Operating noise is heard. |
Cut off the No. 2 fuel injector |
| Engine is changed (becomes unstable) | ||
7 | Fuel injector cylinder #3 | Drive the No. 3 fuel injector |
| Operating noise is heard. |
Cut off the No. 3 fuel injector |
| Engine is changed (becomes unstable) | ||
8 | Fuel injector cylinder #4 | Drive the No. 4 fuel injector |
| Operating noise is heard. |
Cut off the No. 4 fuel injector |
| Engine is changed (becomes unstable) | ||
9 | Glow PWM <Euro 6b or Euro 6c> | Approximately 30% fixed PWM Duty | Ignition switch: "ON" position | The glow lamp turns on. |
10 | Throttle valve | Drive the throttle valve into 0 to 81.4 deg position |
| Throttle valve is driven into 0 to 81.4 deg position. |
11 | EGR valve opening degree | Drive the EGR valve into 0 to 73 deg position |
| EGR valve is driven into 0 to 73 deg position. |
12 | Turbocharger opening degree | Open the turbocharger into 0 to 100% |
| The turbocharger is opened into 0 to 100%. |
13 | Engine oil pressure control solenoid valve <Euro 4 (Vehicles for Indonesia or Mexico), Euro 5b, Euro 6b or Euro 6c> | Variable engine oil pressure control solenoid valve duty in 0 to 25% |
| Oil pressure rises after 0% duty. |
14 | Glow relay <Euro 2 or Euro 4> | Turn ON/OFF the glow plug relay. | Ignition switch: "ON" position | Battery voltage applied to the glow plug when the glow plug relay is ON. |
15 | Bypass control valve <SHP engine> | Turn ON/OFF the compressor bypass valve |
| Compressor bypass valve drives. |
16 | Turbine bypass valve <SHP engine> | Open the turbine bypass valve into 0 to 100% |
|
|
17 | Wastegate valve <SHP engine> | Waste gate valve drives with a duty value of 0 or 100% |
| Operating sound of the waste gate valve is heard. |
18 | Electric W/P <Euro 6b or Euro 6c> | Electric water pump drives with a duty value into 10 or 80% |
| Operating sound of the electric water pump is heard. |
Item No. | M.U.T.-III SE display | Content |
1 | Supply pump learning initialization | Initialise supply pump learning |
Item No. | M.U.T.-III SE display | Drive contents | Inspection conditions | Normal condition |
1 | Injector quantity compensation | Learn the injection quantity of the injector |
| Set the learning complete flag |
Item No. | M.U.T.-III SE display | Drive contents | Inspection conditions | Normal condition |
1 | SCR system warning reset <Euro 6b or Euro 6c> | Initialise the learning values related to urea SCR system | Ignition switch: "ON" position | Learning values related to urea SCR system are initialised. |
2 | Clear when replacing DPF <Euro 5b, Euro 6b or Euro 6c> | Initialise the learning values related to DPF |
| Learning values related to DPF are initialised. |
Item No. | M.U.T.-III SE display | Drive contents | Inspection conditions | Normal condition |
1 | Starter counter <Vehicles with AS&G system> | Set the number of times the starter actuating during normal startup |
| The indicated value is reflected to "the number of times the starter actuating". |
2 | Starter counter (AS&G) <Vehicles with AS&G system> | Set the number of times the starter actuating during auto stop & go (AS&G) |
| The indicated value is reflected to "the number of times the starter actuating (AS&G)". |