ENGINE - DIESEL FUEL<4N1> - TROUBLESHOOTING - DIAGNOSIS CODE PROCEDURES - P0079-00 Exhaust valve control solenoid bank 1<SHP engine>
DTC Description: P0079-00
N502552840000400ENG
DIAGNOSIS CODE DETECTION LOGIC
Diagnosis Code No.
M.U.T.-III SE Screen Items
[Diagnosis item]
Diagnosis Code Detection Condition
P0079-00
Exhaust valve control solenoid bank 1
[V.V.T. control solenoid valve circuit (low)]
Diagnosis condition
  • Battery positive voltage is 8 to 16 V.
  • 2 seconds later after the ignition switch has been in "ON" position or the engine has started up.
Signal (terminal)
V.V.T. control solenoid valve.
Threshold
The return pulse is stuck on the earth side when the drive duty to the exhaust V.V.T. is not 0%.
Diagnosis delay time
2 seconds
POSSIBLE CAUSE
  • Failed V.V.T. control solenoid valve.
  • Open/short circuit or harness damage in V.V.T. control solenoid valve circuit or loose connector contact.
  • Failed engine-ECU.
FAIL-SAFE AND BACKUP FUNCTION
  • The V.V.T. system control is stopped.
  • The small injection quantity learning is prohibited.
  • The cruise control is prohibit. <Vehicles with cruise control system>
DIAGNOSIS CODE CONFIRMATION PROCEDURE
1.Preconditioning
If "Diagnosis Code Confirmation Procedure" has been previously conducted, always turn the ignition switch to the "LOCK" (OFF) position and wait at least 65 seconds before conducting the next test.
2.Diagnosis code confirmation procedure
CAUTION:
To prevent damage to the M.U.T.-III SE, always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting the M.U.T.-III SE.
With M.U.T.-III SE
  1. Start the engine and wait for 10 seconds or more in idling condition.
    NOTE:
    When the engine cannot be started, crank the engine for 5 seconds or more.
  2. Perform "Self-diagnosis" of engine-ECU using M.U.T.-III SE.
Is diagnosis code No. P0079-00 set?
YES
NO-1
To check malfunction symptom before repair: Check intermittent incident (Refer to General Information – General – Basic Inspection – Service Information for Electrical Incident – INTERMITTENT INCIDENT).
NO-2
Confirmation after repair: Inspection end.
BookmarkedToo many bookmarks.