Diagnosis Code No. | M.U.T.-III SE Screen Items [Diagnosis item] | Diagnosis Code Detection Condition | |
P0192-00 | Fuel rail pressure sensor bank 1 [Rail pressure sensor malfunction] | Diagnosis condition |
|
Signal (terminal) | Rail pressure sensor | ||
Threshold | The rail pressure sensor output voltage is 0.27 V or less. | ||
Diagnosis delay time | – | ||