TURBOCHARGER COMPRESSOR BYPASS VALVE ACTUATOR CHECK <4N1 SUPER HIGH-POWER ENGINE>N502580390000F00ENG
Remove the intercooler air hose.
Connect the hand vacuum pump to the nipple of the compressor bypass valve.
Also check operation of the compressor bypass valve.
| | Negative pressure | Valve operation | approximately 50 kPa | Opening |
|
Check that the actuator link is operating.